期刊文献+

聚茜素红膜修饰电极对多巴酚丁胺的测定研究 被引量:3

Determination of dobutamine at poly(alizarin red) film modified electrode
下载PDF
导出
摘要 利用循环伏安法研究了多巴酚丁胺在聚茜素红膜修饰玻碳电极(PAR/GCE)上的电化学行为.实验结果表明;聚茜素红膜修饰电极对多巴酚丁胺具有良好的富集作用。在最佳实验条件下·采用示差脉冲伏安法,多巴酚丁胺的浓度与其氧化峰电流在5.0×10^-8~7.0×10^-5mol·L^-1范围呈良好线性关系,相关系数为0.9972,检测限为1.5×10^-8mol·L^-1(信噪比为3).采用同一修饰电极连续测定40次或每次测定前重新修饰同一电极连续测定10次,标准偏差分别为3.2%和3.7%,表明该修饰电极具有良好的重现性.利用该修饰电极测定了多巴酚丁胺注射剂和血清样品中多巴酚丁胺的含量,获得了满意的实验结果. The electrochemical behavior of dobutamine in poly (alizarin red) film modified electrodes (PAR/GCE) has been studied by cyclic vohammetry. The experiments show good effect of accumulation on dobutamine in this modified electrode. On optimal conditions, a good linear relationship between anodie peak current and dobutamine concentration was obtained in the range of 5.0 × 10^-8-7.0 × 10^-5 mol · L^-1 with the detection limit of 1.5 × 10^-8 mol · L^-1 (S/N=3) by differential pulse voltammetry. The responses of repeated measurements at the identical and renewed surface of the PAR/GCE were examined with relative standard deviation of 3.2% (n=40) and 3.7% (n=10), respectively. The result indieats the excellent reproducibility of the chemically modified electrode. The proposed method has been used to determine dobutamine concentration in serum and dobutamine injection samples with satisfactory results.
出处 《扬州大学学报(自然科学版)》 CAS CSCD 2006年第4期29-33,共5页 Journal of Yangzhou University:Natural Science Edition
基金 国家自然科学基金资助项目(20375034) 物理化学国家重点学科培育点项目资助
关键词 聚茜素红膜修饰电极 示差脉冲伏安法 多巴酚丁胺 poly (alizarin red) modified electrode differential pulse voltammetry dobutamine
  • 相关文献

参考文献19

二级参考文献64

共引文献79

同被引文献24

  • 1唐国风,黄玉明,石文兵,刘卫兵.流动注射化学发光测定盐酸多巴酚丁胺[J].西南师范大学学报(自然科学版),2004,29(4):638-641. 被引量:2
  • 2汪振辉,张岱,张岩,周漱萍.多巴酚丁胺在聚对氨基吡啶化学修饰电极上的电化学行为及其吸附溶出伏安法测定[J].分析试验室,2004,23(8):9-13. 被引量:4
  • 3张延琪,徐静,宋小杰,夏传俊,魏先文.磷钨酸铈/碳纳米管复合材料的合成及其催化性能[J].安徽师范大学学报(自然科学版),2005,28(3):306-308. 被引量:5
  • 4冯建章,童沈阳.苯醌类试剂用于测定多巴酚丁胺的研究[J].北京大学学报(自然科学版),1996,32(4):431-435. 被引量:4
  • 5CHENXin-qian(陈新谦),JINYou-yu(金有豫),新编药物学.第十三版.北京:人民卫生出版社,1992.260.
  • 6Kanna Rao KV, Reddy MN. Spectrophotometric determination of dobutamine hydrochloride in pharmaceutical formulations. Asian J Chem ,2001,13 (4) : 1535.
  • 7Eflour LC, Dine T, Luyckx M. Solid phase extraction and high per- fommnce liquid chromatographic deterurnination of dobutamlne in plasma of dialysed patients. J Chromatogr Biomed Appl, 1994, 8 (6) :309.
  • 8LIU Hai -yan,ZHANG Ling,ZHOU Jing- ming,et al. Flow injec- tion chemiluminescence determination of dobutamine hydrochloride injection using lumiuol - ferricyanide/ferrocyanide system. Anal Chim Acta,2005,541:125.
  • 9Chernyshov DV, Shvedene NV, Antipova ER, et al. Ionic liquid - based miniature electrochemical sensors for the vohammetric deter- mination of catecholamines. Anal Chim Acta ,2008,621:178.
  • 10WEI Yan, KONG Ling - tao, YANG Ran,et al. Electrochemical im- pedance determination of polychlorinated biphenyl using pyrenecy- clodextrin - decorated single - wailed carbon nanotube hybrid. Chem Commun ,2011,47:5340.

引证文献3

二级引证文献1