计算大窗墙比的建筑冷负荷,分析冷负荷形成特点、空调能耗状况和系统的经济性;讨论了幕墙门窗面积、朝向和玻璃材料对冷负荷的影响;对幕墙门窗选用6种不同玻璃材料时形成的夏季冷负荷进行计算,在分析节能效果和经济效益的基础上,确定较为合理的玻璃材料。
The cooled load of the great proportion of the whole glass curtain wall and the common enclosing wall was calculated . The character of cooled loads and the energy consumption of air conditioning and the economy were analysed. The factors such as glass curtain wall area, orientation and the material which are affected on cooled load were discussed. Cooled loads of six kinds of glass in summer were calculated. Based on the analysis of the energy-saving effect and economic benifits, the reasonable glass was got.