期刊文献+

N_2O_4中铝含量的测定

Measurement of the Aluminum Content in N_2O_4
下载PDF
导出
摘要 提出了一种用分光光度计测定N2O4中铝含量的方法。先对样品进行预处理以消除N2O4本身颜色对比色的影响。给出了测定步骤。由实验确定的操作条件是:显色剂为玫红三羧酸铵溶液0.5 g/L,最佳用量5 mL,最大吸收波长530 nm。实验表明,该法测得的N2O4中铝含量的相对标准偏差小于5%,回收率大于96%。方法准确可靠。 A measurement method of aluminum content in N2O4 using spectrophotometry was put forward in this paper. The pretreatment of the N2O4 sample was adopted to eliminate the influence of N2O4 's color on the colorimetric. The t step was given. The test condition determined by experiment was that colour regent was 0.5 g/L ammonium aurin tricarboxylate solution with optimal 5 mL dosage and maximum absorbing wavelength was 530 nm. The test showed that the relative standard deviation of aluminum content in N2O4 measured by this method was smaller than 5%, and recovery rate was bigger than 96 %, The method was accurate and reliable.
出处 《上海航天》 北大核心 2006年第6期58-60,共3页 Aerospace Shanghai
关键词 N2O4 铝含量 分光光度法 预处理 测定条件 相对标准差 回收率 Nitrogen tetroxide Aluminium content Spectrophotometry Pretreatment Measurement condition Relative standard deviation Recovery rate
  • 相关文献

参考文献3

  • 1王跃志,王淑芬,崔玉祥,等.GJB 1673-1993 N2O4规范[S].北京:国防科学技术工业委员会,1993.
  • 2杨葆真,王化圣.GB/T 9734-1988化学试剂铝测定通用方法[S].北京:中国化学工业部,1988.
  • 3天津化学试剂一厂.GB/T 602-1988 化学试剂杂质测定用标准溶液的制备[S].北京:中国化学工业部,1988.