期刊文献+

根尖定位仪应用于牙根纵裂的临床诊断 被引量:4

Application of root apex locator to diagnose vertical root fracture
下载PDF
导出
摘要 目的研究应用根尖定位仪诊断牙根纵裂。方法用根尖定位仪测量36例患牙的每个根管工作长度,并进行比较。结果发生纵裂的牙根,其根管工作长度明显短于对照牙根的工作长度,拔除患牙后证实:根纵裂的位置与测量结果一致。结论根尖定位仪有助于牙根纵裂的临床诊断。 Objective To study the application of root apex locator to diagnose vertical root fracture. Methods We used the root apex locator to measure work length of each root canal of 36 cases and compared the measured results. Results The work length of root canal with vertical root fracture was obviously shorter than that of the compared root canal. After the teeth with vertical root fracture were pulled out, it was confirmed that the location of vertical root fracture accorded with the measured results. Conclusion The root apex locator is very helpful in diagnosing vertical root fracture.
作者 柏宁 梅予锋
出处 《口腔医学》 CAS 2006年第6期443-444,共2页 Stomatology
关键词 根尖定位仪 诊断 牙根纵裂 root apex locator diagnose vertical root fracture
  • 相关文献

参考文献7

二级参考文献33

  • 1曹采方 王满恩.牙根裂[J].中华口腔科杂志,1981,16:235-235.
  • 2Walton RE, Torabinejad M. Principles and Practice of Endodontics[M]. 3rd Edition. W. B. Saunders Company, 1999.499.
  • 3Sornkul E, Stannards JG. Strength of roots before and after endodontic treatment and restoration [ J ]. J Endod, 1992,18:440.
  • 4Tamse A. latrogenic vertical root fractures in endodontically treated Teeth [ J ]. Endod Dent Traumatol , 1988,4 : 190.
  • 5Tamse A, Fuss Z, Lustig J. An evaluation of endodontically treated vertically fractured teeth [ J ]. J Endod, 1999,25 (7) :506.
  • 6Tamse A, Fuss Z, Lustig J. Radiographic features of vertically fractured, endodontically treated Maxillary premolars [ J ]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod,1999,88:348.
  • 7吴奇光,口腔组织病理学(第3版),1994年,18页
  • 8张志良,口腔医学,1989年,9卷,69页
  • 9王嘉德,华西口腔医学杂志,1984年,4卷,233页
  • 10曹采方,中华口腔医学杂志,1981年,16卷,235页

共引文献71

同被引文献42

  • 1薛法义,王素杰,孙汉堂,王晓方.电子根尖定位仪测量根管长度偏差分析[J].牙体牙髓牙周病学杂志,2005,15(6):346-347. 被引量:15
  • 2黎远皋.牙根纵裂的临床观察及病因分析[J].口腔医学,2006,26(1):39-40. 被引量:11
  • 3陈君,岳林,王嘉德,高学军.根管扩大程度与牙根强度和应力分布的关系[J].中华口腔医学杂志,2006,41(11):661-663. 被引量:42
  • 4al Kadi H, Sykes LM, Vally Z. Accuracy of the Raypex-4 and Propex apex locators in detecting horizontal and vertical root fractures: An in vitro study[J]. SADJ, 2006, 61 (6):244-247.
  • 5Ebrahim AK, Wadachi R, Suda H. Accuracy of three different electronic apex locators in detecting simulated horizontal and vertical root fractures[J]. Aust Endod J, 2006, 32(2):64-69.
  • 6Azabal M, Garcia-Otero D, de la Macorra JC. Accuracy of the Justy Ⅱ Apex locator in determining working length in simulated horizontal and vertical fractures[J]. Int Ended J, 2004, 37 (3): 174-177.
  • 7Ebrahim AK, Yoshioka T, Kobayashi C, et al. The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: An in vitro study[J]. Aust Dent J, 2006, 51 (2): 153-157.
  • 8Shabahang S, Goon WW, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator[J]. J Endod, 1996, 22(11):616- 618.
  • 9Dunlap CA, Remeikis NA, BeGole EA, et al. An in vivo evaluation of an electronic apex locator or that uses the ratio method in vital and necrotic canals [J]. J Endodon, 1998,24 (1) : 48-50.
  • 10al Kadi H, Sykes LM, Vally Z. Accuracy of the Raypex-4 and Propex apex locators in detecting horizontal and vertical root fractures: An in vitro study[J]. SADJ, 2006, 61 (6) : 244-247.

引证文献4

二级引证文献24