摘要
目的探索电感耦合等离子体原子发射光谱(ICP-AES)法测定血硼的方法,确定南京地区儿童血硼质量浓度正常值范围。方法全血经1 mol/L HNO3处理后用ICP-AES法测定,并用该方法测定南京地区1 032名健康儿童及1 364名就诊儿童血硼。结果方法精密度为1.60%-4.31%,回收率为93.3%-98.9%。1 032名健康儿童全血硼质量浓度为(41.8±16.7)μg/L,1 364名就诊儿童血硼质量浓度为25.1-58.5μg/L(77%)。结论全血经硝酸处理后测定血硼,精密度及回收率均较理想,可以作为测定血硼的参考方法。并初步提出该方法的南京地区儿童血硼参考范围为25.1-58.5μg/L(1岁以下儿童除外)。
Objective To study inductively coupled plasma atomic emission spectrometry (ICP-AES) used to determine blood boron (B), and to investigate the level of B in blood of children in Nanjing. Methods ICP-AES was applied to determine the level of B in the blood of 1 032 healthy children and 1 364 children patients after using 1 mol/L HNO3 to treat whole blood. Results Precision of this method was 1.60% - 4.31%, and recovery ratio was 93.3 % -98.9%. The level of B in blood of the 1 032 healthy children was (41.8 ± 16.7) μg/L and that in blood of the 1 464 patients was (25.1±58.5) μg/L (77%). Conclusion Precision and recovery ratio determined by the method are high, so. it can be used as a reference method to detect the level of B in blood. And it preliminarily determines the reference levels of blood B of children in Nanjing as ranging from 25.1-58.5μg/L (except children below 1 year old).
出处
《西安交通大学学报(医学版)》
CAS
CSCD
北大核心
2006年第6期618-619,F0003,共3页
Journal of Xi’an Jiaotong University(Medical Sciences)
关键词
ICP-AES
血硼
儿童
Inductively coupled plasma atomic emission spectrometry (ICP-AES)
boron in blood
child