期刊文献+

Impact of Suspended Particles and Enhancement Techniques on Ultraviolet Disinfection of a Secondary Effluent

Impact of Suspended Particles and Enhancement Techniques on Ultraviolet Disinfection of a Secondary Effluent
下载PDF
导出
摘要 The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is difficult to achieve sometimes. The authors studied the particle size distribution, contribution of particle-associated Fecal Coliform (F.C.), and their influences on UV disinfection. A combined disinfection process (chlorination with a subsequent UV disinfection) was tested to improve the disinfection effect. The results indicated that the content of suspended solids, especially that of large particles, has a strong impact on UV disinfection efficiency; D>10 μm particles associated F.C. are difficult to be disinfected and are the main part of the tailings of F.C. inactivation curves. Pre-chlorination could decrease the number of particles in the secondary effluent and transform the large particles into small ones, reducing the influence of particles on UV disinfection and enhancing the resistance ability of the combined process to particle loading. The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is difficult to achieve sometimes. The authors studied the particle size distribution, contribution of particle-associated Fecal Coliform (F. C. ), and their influences on UV disinfection. A combined disinfection process (chlorination with a subsequent UV disinfection) was tested to improve the disinfection effect. The results indicated that the content of suspended solids, especially that of large particles, has a strong impact on UV disinfection efficiency; D〉 10 μm particles associated F.C. are difficult to be disinfected and are the main part of the tailings of F.C. inactivation curves. Pre-chlorination could decrease the number of particles in the secondary effluent and transform the large particles into small ones, reducing the influence of particles on UV disinfection and enhancing the resistance ability of the combined process to particle loading.
出处 《Journal of Ocean University of China》 SCIE CAS 2006年第4期381-386,共6页 中国海洋大学学报(英文版)
关键词 污水处理厂 二级出水 紫外消毒 悬浮颗粒 强化技术 effluent disinfection biotoxicity Chlorination/UV combined disinfection
  • 相关文献

参考文献1

二级参考文献17

  • 1顾平,颜育平.回用水紫外线消毒[J].城市环境与城市生态,1993,6(3):15-20. 被引量:11
  • 2黄君礼 寇广中.游离性和化合性有效氯对氯仿形成的影响[J].环境科学,1987,8(5):21-21.
  • 3汪大翠 雷乐成.水处理新技术及工程设计[M].北京:化学工业出版社,2001,5.196-197.
  • 4Meulemans C. C.E. The basic principles of UV-disinfection of water. Ozone Sci. Eng., 1987,(9):299-314
  • 5Braunstein J., et al. Ultraviolet disinfection of filtered activated sludge effluent for reuse applications. Wat. Envir. Res.,1996,69(2): 152-161
  • 6Kuo J., Surampali R. Water reclamation and reuse criteria in the U.S. Wat. Sci. Tech., 1996,33(10-11):451-462
  • 7R. J. Qualls, M.P. Flynn, et al. The role of suspended particles in ultraviolet disinfection. J. Water Pollut. Control Fed.,1983,55:1280-1285
  • 8Whitby E. , et al. The effect of UV transmission, suspended solids and photoreactivation on microorganisms in wastewater treated with UV light. Wat. Sci. Tech., 1993, 27(3-4):379-386
  • 9White S. C., et al. A study of operational ultraviolet disinfection equipment at secondary treatment plants. J. Water Pollut.Control Fed., 1986,58:180-187
  • 10Levine A., et al. Characterization of the size distribution of contaminants in wastewater: Treatment and reuse implications. J. WPCF, 1985,57(7): 805-816

共引文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部