摘要 通过10个不同连接构造的足尺钢梁柱刚性连接节点的试验,研究了标准栓焊连接节点、标准全焊连接节点、梁翼缘加强型节点、梁翼缘局部削弱型节点以及梁贯通型节点在梁端往复荷载作用下的破坏过程、破坏形态、承载力和塑性变形能力等抗震性能。试验结果表明,梁翼缘局部切割削弱和梁翼缘加盖板节点的梁的极限塑性转角大于0.03,梁贯通型节点、梁下翼缘加腋节点和梁翼缘打孔节点的梁的极限塑性转角大于0.02,其余类型节点的都小于0.02。对实测的梁翼缘和腹板的应力分布的分析表明,梁根部翼缘处于三向应力状态,是其脆性断裂破坏的原因之一。建议钢框架梁柱连接优先采用梁翼缘加梯形盖板节点和梁下翼缘加腋节点。 Ten different full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic deformation capacity. The specimens consisted of one conventional welded flange-bolted web connection, one conventional fully welded connection, four beam flange strengthened connections, three beam flange weakened connections and one through-diaphragm connection. Test results show that the beam ultimate plastic rotation of connections with flange cover plates or with partial cut flanges is larger than 0.03, that of through - diaphragm connection and connections with bottom beam haunch or with perforated beam flanges is larger than 0.02, that of other type connections is less than 0.02. The measured stress profiles along the beam flange and the beam web depth show that the tri-direction stress state at the flange of beam end is one of the causes of brittle fracture occurred at the beam end. Beamto-column moment connections with beam flange cover plates or with bottom beam haunch are recommended first for steel MRFs.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2006年第6期18-27,73,共11页 Journal of Building Structures
关键词 钢梁柱刚性连接节点 足尺试件 破坏形态 塑性转角 试验研究 steel beam-to-column moment connection full-scale specimen failure mode plastic rotational angle experimental study
  • 相关文献

参考文献13

  • 1Youssef N,Bonowitz D,Gross J L.A survey of steel momentresisting frame buildings affected by the 1994 Northridge earthquake[R].National Institute of Standards and Technology,NISTIR 5625,1995.
  • 2Ojdrovic R P,Zarghamee M S.Fractures of steel moment connections in the Northridge earthquake[J].Proceedings of the Institution of Civil Engineers:Structures and Buildings,1997,123:209-217.
  • 3Mahin S A,Miller D K.Lessons learned from the Northridge earthquake[J].Engineering Structures,1998,20 (4-6):249-260.
  • 4Nakashima M,Bruneau M.Preliminary reconnaissance report of the 1995 Hyogoken-Nanbu earthquake[R].Architectural Institute of Japan,Tokyo,1995.
  • 5Gates W E,Morden M.Professional structural engineering experience related to welded steel moment frames following the Northridge earthquake[J].The Structural Design of Tall Buildings,1996,5(1):29-44.
  • 6Popov P E,Yang T S,Chang S P.Design of steel MRF connections before and after 1994 Northridge earthquake[J].Engineering Structures,1998,20 (12):1030-1038.
  • 7Nakashima M,Suita K,Morisako K,Maruoka Y.Tests of welded beam-column subassemblies,Ⅰ:Global behavior[J].Journal of Structural Engineering,ASCE,1998,124 (11):1236-1244.
  • 8Lu L W,Ricles J M,Mao C S,Fisher J W.Critical issues in achieving ductile behavior of welded moment connections[J].Journal of Constructional Steel Research,2000,55:325-341.
  • 9Engelhardt M D,Sabol T A.Reinforcing of steel moment connections with cover plates:benefits and limitations[J].Engineering Structures,1998,20(4-6):510-520.
  • 10宋振森,顾强,郭兵,SONG Zhensen,GU Qiang,GUO Bing.刚性钢框架梁柱连接试验研究[J].建筑结构学报,2001,22(1):53-57. 被引量:44

二级参考文献8

  • 1[1]William E Gates, Manuel Morden. Professional Structural Engineering Experience Related to Welded Steel MomentFrames Following the Northridge Earthquake[J]. The Structural Design of Tall Buildings, 1996, 5(1): 29 -44.
  • 2[2]Duane K Miller. Lessons Learned from the NorthridgeEarthquake [J]. Engineering Structures, 1998, 20 (4-6):249 - 260.
  • 3[3]Egor Paul Popov, Tzong-shuoh Yang and Shih-po Chang.Design of Steel MRF Connections before and after 1994Northridge Earthquake[J]. Engineering Structures, 1998, 20(12): 1030-1038.
  • 4[5]GB 50011-2001,建筑抗震设计规范[S].
  • 5[6]FEMA. Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings[J]. USA: Federal Emergency Management Agency, 2000.
  • 6[7]Le-wu Lu et al. Critical Issues in Achieving Ductile Behavior of Welded Moment Connections[J]. Journal of Constructional Steel Research, 2000, 55(1-3): 325-341.
  • 7JGJ 99-88高层民用建筑钢结构技术规程
  • 8赵大伟,石永久,陈宏.低周往复荷载下梁柱节点的试验研究[J].建筑结构,2000,30(9):3-6. 被引量:36

共引文献113

同被引文献206

引证文献20

二级引证文献79

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部