期刊文献+

An evaluation of force-based design vs.direct displacement-based design of jointed precast post-tensioned wall systems 被引量:10

An evaluation of force-based design vs.direct displacement-based design of jointed precast post-tensioned wall systems
下载PDF
导出
摘要 The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tensioning to attach the walls to the foundation, along with employing energy dissipating shear connectors between the walls. Using acceptance criteria defined in terms of inter-story drift, residual drift, and floor acceleration, this study presents a multiplelevel performance-based seismic evaluation of two five-story unbonded post-tensioned jointed precast wall systems. The design and analysis of these two wall systems, established as the direct displacement-based and force-based solutions for a prototype building used in the PREcast Seismic Structural Systems (PRESSS) program, were performed at 60% scale so that the analysis model could be validated using the PRESSS test data. Both buildings satisfied the performance criteria at four levels of earthquake motions although the design base shear of the direct displacement-based jointed wall system was 50% of that demanded by the force-based design method. The study also investigated the feasibility of controlling the maximum transient inter-story drift in a jointed wall system by increasing the number of energy dissipating shear connectors between the walls but without significantly affecting its re-centering capability. The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tensioning to attach the walls to the foundation, along with employing energy dissipating shear connectors between the walls. Using acceptance criteria defined in terms of inter-story drift, residual drift, and floor acceleration, this study presents a multiplelevel performance-based seismic evaluation of two five-story unbonded post-tensioned jointed precast wall systems. The design and analysis of these two wall systems, established as the direct displacement-based and force-based solutions for a prototype building used in the PREcast Seismic Structural Systems (PRESSS) program, were performed at 60% scale so that the analysis model could be validated using the PRESSS test data. Both buildings satisfied the performance criteria at four levels of earthquake motions although the design base shear of the direct displacement-based jointed wall system was 50% of that demanded by the force-based design method. The study also investigated the feasibility of controlling the maximum transient inter-story drift in a jointed wall system by increasing the number of energy dissipating shear connectors between the walls but without significantly affecting its re-centering capability.
机构地区 [ [
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2006年第2期285-296,共12页 地震工程与工程振动(英文刊)
关键词 CONCRETE PRECAST unbonded post-tensioning WALL building code performance-based evaluation force-baseddesign direct-displacement based design concrete precast unbonded post-tensioning wall building code performance-based evaluation force-baseddesign direct-displacement based design
  • 相关文献

参考文献10

  • 1Tong M,Lee G,Rzhevsky V,Qi J,and Shinozuka M.“A Comparison of Seismic Risk of Nonstructural Systems in a Hospital Before and After a Major Structural Retrofit,”[].ATC-- Seminar on Seismic Design Retrofit and Performance of Nonstructural Components in Critical Situations.2004
  • 2Priestley MJN,Sritharan S,Conley JR,and Pampanin S.“Preliminary Results and Conclusions From the PRESSS Five-Story Precast Concrete Test Building,”[].PCI Journal.1999
  • 3Seismology Committee.Recommended Lateral Force Requirements and Commentary (Blue Book)[]..1999
  • 4.Acceptance Criteria for Special Unbonded Post-tensioned Structural Walls Based on Validation Testing[].ITG -XX.2006
  • 5Carr AJ.“RUAUMOKO — Inelastic Dynamic Analysis Program,”[]..2003
  • 6Priestley MJN.“Direct Displacement-basedDesign of Precast/Prestressed Concrete Buildings,”[].PCIJournal.2002
  • 7Sritharan S,and Rahman MA.“Performance-based Seismic Assessment of Two Precast Concrete Hybrid Frame Buildings,”[].Proceedings of International Workshop on Performance-based Seismic Design.2004
  • 8Sritharan S.“Performance of Four Jointed Precast Frame Systems Under Simulated Seismic Loading,”[].Proceedings of the Seventh National Conference on Earthquake Engineering; Paper No.2002
  • 9Kurama Y,Pessiki S,Sause, R,and Lu L.“Seismic Behavior and Design of Unbonded Post-Tensioned Precast Concrete Walls,”[].PCI Journal.1999
  • 10Galusha JG.“Precast, Post-tensioned Concrete Walls Designed to Rock,”[]..1999

同被引文献63

引证文献10

二级引证文献170

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部