将镀镍层剥离溶解,用配合滴定法测定镀层中镍的含量,通过计算间接求出磷的含量.该法所得的磷含量与重量法测定结果比较,仅相差3%左右.
After the Ni-P coating was dissolved, nickel content was determined by coordination titration, and then phosphorus content was obtained by calculating. The relative error is under 3 % compared with the test result of weight method.