摘要
采用基于电动车电池测试规范的超级电容器恒流充放电循环测试时间序列,研究了大电流充放电循环寿命试验中,超级电容器有效容量、充放电持续时间步长等性能指标的衰减规律,以及热能集中、电热击穿等因素诱发的超级电容器瞬间爆燃、表面塌陷等失效模式.
Based on electric vehicle battery test criterion, the time-sequence of constant-current charging/ discharging cycle test for supercapacitors was applied. Under the experiment of high current charge/discharge cycle lifetime,the characteristics attenuation of the available capacity and charging/discharging duration of supercapacitors were studied. And also some failure modes for deflagration and shell softening were explored, which were caused by heat energy cumulation and electrical-thermal breakdown.
出处
《兰州交通大学学报》
CAS
2006年第6期8-11,共4页
Journal of Lanzhou Jiaotong University
关键词
超级电容器
快速充放电试验
性能衰减
失效模式
supercapacitor
rapid charging/discharging cycles
performance attenuation
failure modes