低场强MRI的动态增强扫描在乳腺肿块诊断中的应用探讨(附15例报告)

Low-magnetic field MR dynamic Gadolinium-enhanced techniques in diagnosis of breast mass: a report of 15 cases
下载PDF
导出
摘要 目的探讨低场强MR机动态增强扫描对乳腺肿块诊断的可行性和应用价值。方法对15例临床扪诊乳腺肿块患者进行MRI动态增强扫描,其中7例选用FSE-T1WI系列进行扫描、5例选用SESS-T1WI系列进行扫描、3例选用GRL-T1WI系列进行扫描。乳腺肿块的性质以病理结果为依据。结果FSE-T1WI可以获得0.5、1、1.5、2、3、5、7、10min不同时间内的增强扫描像,SESS-T1WI可以获得1、3、5、7、10min不同时间内的增强扫描像,GRL-T1WI可以获得1.5、3、5、7、10min不同时间内的增强扫描像。虽然不能达到高场MR机那样的动态增强效果,但能达到较满意观察病变强化过程的目的。结论低场强MR机若能选择适当参数,进行乳腺肿块的动态增强扫描是可行的,可作为较理想的临床上用于乳腺肿块诊断与鉴别诊断的影像学检查方法。 Objective To evaluate the feasibility and applicable value of low - magnetic field MR dynamic Gadolinium- enhanced techniques in diagnosis of breast mass. Methods 15 patients clinically diagnosed with breast mass were given MR Gadolinium- enhanced scanning, of 7 cases received FSE- T1WI sequence scanning, of 5 cases received SESS - T1WI sequence scanning, of 3 cases received GRL- T1WI sequence scanning. The classification of the breast mass based on the pathological examination results. Results In FSE- T1WI sequence, the imaging enhancement were obtained at 0.5 min, 1 min, 1.5 min, 2 min, 3min, 5 min, 7 min, and 10 min; and in SESS- T1WI sequence, the imaging enhancement were obtained at 1 min, 3 min, 5 min, 7 min and 10 min; and in GRL- T1WI, the imaging enhancement were obtained at 1.5 min, 3 min, 5 min, 7 min and 10 min. Though the images could not have high resolution as high - magnetic field MR Gadolinlium - enhanced scanning, but it can observe the lesions enhanced satisfactorily. Conclusion If the sequence is selected appropriately, low- magnetic field MR dynamic Gadolinium - enhanced screening for breast mass is feasibility, it can be used as an imaging examination method.
出处 《右江民族医学院学报》 2007年第1期10-12,共3页 Journal of Youjiang Medical University for Nationalities
关键词 磁共振成像 乳腺肿瘤 诊断 magnetic resonance imaging breast neoplasms diagnosis
  • 相关文献

参考文献7

二级参考文献24

  • 1黄力,王宁霞.MRI诊断扪诊阴性的乳腺占位性疾病[J].中华放射学杂志,1997,31(2):119-122. 被引量:8
  • 2[1]Kerslake RW, Carleton PJ, Fox JN, et al. Dynamic gradientecho and fatsuppressed spin-echo contrast-enhanced MRI of the breast[J]. Clinical Radiology, 1995,50: 440-454.
  • 3[2]Kramers S, Schulz-Wendtland R, Hagedorn K, et al. Magnetic resonance imaging and its role in the diagnosis of multicentric breast cancer[J]. Anticance Res,1998, 18:2163-2164.
  • 4[3]Friedman EP, Hall-Craggs MA, Mumtaz H, et al. Breast MR and the appearance of the normal and abnormal nipple[J]. Clin Radiol,1997, 52:854-861.
  • 5[4]Boetes C, Mus RDM, Holland R, et al. Breast tumours: comparative accuracy of MR imaging relative to mammography and US for demonstrating extent[J]. Radiology, 1995, 197:743-747.
  • 6[5]Davis PL, Staiger MJ, Harris KB,et al. Breast cancer measurements with magnetic resonance imaging, ultrasonography, and mammography[J]. Breast Cancer Res Treat, 1996, 37:1-9.
  • 7[6]Heywang SH, Beck R. Contrast-Enhanced MRI of the breast heidelberg[J]. Springer Verlag, 1996, 95-103.
  • 8[7]Frouge C, Guinebretiere JM, Contesso G, et al. Correlation between contrast enhancement in dynamic magnetic resonance imaging of the breast and tumor angiogenesis[J]. Invest Radiol, 1994, 29:1043-1049.
  • 9[8]Buadu LD, Murakami J, Murayama S, et al. Breast lesions:correlation of contrast medium enhancement patterns on MR imaging with histopathologic findings and tumor angiogenesis[J]. Radiology,1996, 200:639-649.
  • 10[9]Malue S, Wurdinger S, Moritz A, et al. Comparison of written reports of mammography, sonography and magnetic resonance mammography for preoperative evaluation of breast lesions,with special emphasis on magnetic resonance mammography[J].Breast Cancer Res, 2001,3: 55-60.

共引文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部