摘要
本文提出一种新的高灵敏度测定总悬浮颗粒中有机碳的方法一元素分析法。该方法是在氧化炉最佳温度为600℃时,一步测定出样品中有机碳的含量,并成功地对齐齐哈尔市大气总悬浮颗粒中的有机碳进行了连续的监测。结果表明,总悬浮颗粒中有机碳的含量有较明显的变化规律。
A new highly sensitive elemental analysis method for the determination of organic carbon in total suspended particulate matter.When the best combustion furnace temperature is 600℃,the organic carbon is determined directly.The organic carbon of the total suspended particulate matter in Qiqihar is monitored continuously.The result shows that the organic carbon content of the lotal suspended particulate matter has obviously character.
出处
《中国环境监测》
CSSCI
CSCD
北大核心
1996年第4期16-18,共3页
Environmental Monitoring in China
关键词
元素分析
总悬浮颗粒
有机碳
大气监测
elemental analysis,total suspended particulate matter,organic carbon,air monitoring