摘要 结合变风量空气处理系统的设计,介绍了利用室外低温低比焓空气供冷的自然冷却节能技术。对该节能技术的两种形式——空气节能器与水节能器进行了比较。给出了空气节能器的判别控制方法及各方法的适用地区。最后介绍了设计时的注意要点。 With the desigh of VAV air conditioning system, presents the energy saving technology of natural cooling by cooling air conditioned rooms with outdoor air of low temperature and low enthalpy, Compares the two energy saving modes, i.e. air economizer and water economizer. Represents the control discrimination methods of air economizer and their applicability. Gives some important points to be noted during design process.
出处 《暖通空调》 北大核心 2007年第1期68-72,共5页 Heating Ventilating & Air Conditioning
关键词 内区 供冷 空气节能器 固定温度判别法 新风 inner zone, cooling, air economizer, fixed dry bulb temperature method, fresh air
  • 相关文献

参考文献6

  • 1ASHRAE.ANSI/ASHRAE/IESNA Standard 90.1-2001 Energy standard for buildings except low-rise residential buildings[S],2001
  • 2ASHRAE.ANSI/ASHRAE Standard 62-2001Ventilation for acceptable indoor air quality[S]
  • 3ASHRAE.ASHRAE fundamentals handbook 2001[M].Atlanta:American Society of Heating,Refrigerating and Air-conditioning Engineers,2001
  • 4Wang S K.Handbook of air conditioning and refrigeration[M].New York:McGraw-Hill,2000
  • 5空気調和·衛生工学会.空気調和·衛生工学便覧[M].13版,2002
  • 6California Energy Commission.Advanced variable air volume system design guide[S],2003

同被引文献22

  • 1毕敏娜,王清阳,胥布工.兼顾室内空气品质和节能的新风控制[J].制冷与空调(四川),2005,19(3):12-15. 被引量:3
  • 2Ye Yao,Li Wang. Energy analysis on VAV system with different air-side economizers in China[J].Energy and Buildings,2010.1220-1230.
  • 3Kuei-Peng Lee,Hsiang-Lun Chen. Analysis of energy saving potential of air-side free cooling for datacenters in worldwide climate zones[J].En-ergy and Buildings,2013.103-112.
  • 4AirTest. Economizer Control Design Guide a White Paper[R].
  • 5N. Nassif,S. Moujaes. A new operating strategy for economizer dampers of VAV system[J].Energy and Buildings,2008,(3):289-299.doi:10.1016/j.enbuild.2007.02.030.
  • 6Nabil Nassif. Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer damp-ers[J].Energy and Buildings,2010.1026-1037.
  • 7B. Fisk,O. Seppanen,J. Huang. Economic Benefits of An Econo-mizer System:Energy Savings and Reduced Sick Leave[J].ASHRAE Transactions,2004,(06).
  • 8Rongxin Yin,Peng Xu,Pengyuan Shen. Case study:Energy savings from solar window film in two commercial buildings in Shanghai[J].Ener-gy and Buildings,2012.132-140.
  • 9周兰兰,潘毅群.某数据中心空调系统设计与节能优化分析[J].暖通空调,2009,39(10):102-107. 被引量:15
  • 10钱峰.成都地区免费供冷系统的可行性和经济性[J].建筑热能通风空调,2010,29(4):61-63. 被引量:2