期刊文献+

止血用ZSM-5沸石的生物相容性评价 被引量:4

Biocmpatibility research of a hemostatic agent-ZSM-5 zeolite
下载PDF
导出
摘要 目的:对ZSM-5沸石进行生物相容性评价,为开发其作为急救止血材料提供实验室依据。方法:参照我国医疗器械生物学评价标准和所推荐的生物学试验,对ZSM-5沸石进行体外细胞毒性、溶血、急性全身毒性、热原、皮内反应、致敏、微核试验研究。为了解沸石颗粒残留伤口内对机体的影响,行肌肉内植入试验研究。结果:ZSM-5沸石无明显细胞毒性;无溶血反应;急性全身毒性、热原、皮内反应、致敏试验结果均符合我国医疗器械生物学评价标准:沸石植入肌肉后12周局部组织有明显的炎症反应。结论:ZSM-5沸石细胞生物相容性好,但长期存留于创面内可引起炎症反应。 Objective To evaluate the biocompatibility of ZSM-5 zeolite and provide an experimental basis for developing the first-aid hemostatie agent. Methods According to Chinese evaluation standards on medical devices and biological tests, the eytotoxicity in vitro, hemolysis test, acute toxicity of system, pyrogen test, intraeutaneous stimulation, sensitization and micronucleus test were studied in ZSM-5 zeolite. In order to find out the side-effect of the zeolite granules' remains left in the wounds to body, muscle implantation test was studied. Results There were no obvious cytotoxity, hemolysis reaction. Acute tocicity, pyrogen reaction, intraeutaneous stimulation, sensitization and potential mutagenesis in themicronucleus test were observed. Their results were all consistent with the Chinese biological evaluation of medical devices. Obvious inflammatory reaction was observed when ZSM-5 zeolite was implanted in muscle for 12 weeks. Conclusion The ZSM-5 zeolite has reliable biocompatibility. But zeolite can cause inflammatory reaction when it is remained in the wound surface for long term.
出处 《医疗卫生装备》 CAS 2007年第1期22-25,共4页 Chinese Medical Equipment Journal
基金 军队"十一"科技攻关项目资助。
关键词 沸石 生物相容性 MTT试验 肌肉内植入试验 zeolite biocompatibility MTT assay muscle implantation test
  • 相关文献

参考文献12

  • 1Velmahos GC,Demetriades D,Shoemaker WC,et al.Endpoints of resuscitation of critically injured patients:normal or supranormal? A prospective randomized trial[J].Ann Surg,2000,232 (3):409-418.
  • 2Regel G,Stalp M,Lehmann U,et al.Prehospital care,importance of early intervention on outcome[J].Acta Anaesthesiol Scand Suppl,1997,110:71-76.
  • 3GB/T16886.医疗器械生物学评价[S].北京:中国标准出版社,2003.
  • 4曹佳 林真 余争平.微核试验[M].北京:军事医学科学出版社,2000.164-169.
  • 5傅东.天然沸石及其在环保领域中的应用前景[J].中国非金属矿工业导刊,2002(4):30-32. 被引量:21
  • 6Alam HB,Uy GB,Miller D,et al.Comparative Analysis of Hemostatic Agents in a Swine Model of Lethal Groin Injury[J].J Trauma,2003,54(6):1 077-1 082.
  • 7Wright FL,Hua HT,Velmahos G,et al.Intracorporeal Use of the hemostatic Agent QuickClot in a Coagulopathic Patient with Combined Thoracoabdominal Penetrating Trauma[J].Jtrauma,2004,56:205-208.
  • 8Wright JK,Kalns J,Wolf EA,et al.Thermal injury resulting from application of a granular mineral hemostatic agent[J].J Trauma,2004,57(2):224-230.
  • 9蔡谞,王继芳,卢世璧,张笑明,赵斌.无菌性松动假体周围界膜的组织学及超微结构特征[J].中华医学杂志,2000,80(11):826-830. 被引量:10
  • 10Misiek DJ,Kent JN,Carr RF.Soft tissue responses to hydroxylapatite particles of different shapes[J],J Oral Maxillofac Surg,1984,42 (3):150-160.

二级参考文献2

共引文献42

同被引文献103

引证文献4

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部