摘要 针对国内目前血铅测定方法普遍存在的取样量大、仪器设备昂贵、测定步骤多、时间长、分析成本高等缺点,该文通过将电化学传感器技术、现代印刷技术与微机械加工技术相结合,研制出可批量生产的集成型薄膜三电极体系。采用微分脉冲阳极溶出伏安法,只需50μL溶液,在3min时间内就可测出μg/dL水平的微量血铅。pH1.1溶液体系中,铅离子在1.2~70μg/dL的浓度范围内呈现良好的线性关系,线性相关系数为0.998。集成型薄膜三电极检测系统具有快速、准确及低成本等优点,达到现场实时检测的要求。 At present, most domestic methods for analyzing lead concentration of blood suffer from some disadvantages, such as large acquirement of sample amount, high price of apparatus, as well as reiteration of digesting samples, multi - steps and time - costing process, which greatly increase the cost of the analysis. Employing differential pulse anodic stripping voltammetric (DPASV) and integrated three -electrode system, which combines the technology of sensor, modern printing and micro - machining, we can actualize direct microanalysis of lead in one drop of blood (about 50 μL) without digestion in 3 min. The linearity of the standard working curve is good in the range of 1.2 - 70 μg/dL at pH1. 1. The correlation coefficient is 0. 998. Such rapid, accurate, low -costing process can meet the requirement of real - time analysis.
机构地区 复旦大学化学系
出处 《化学传感器》 CAS 2006年第4期18-22,共5页 Chemical Sensors
基金 国家自然科学基金(NSFC#20335040 90606014 20605005 205255192)
关键词 血铅检测 阳极溶出伏安法 集成型薄膜电极 blood lead DPASV integrated film electrode
  • 相关文献

参考文献8

  • 1Albery W J, Cass A E G, Marigold B P, et al. Inhibited enzyme electrodes. Part 3: A sensor for low levels of H2S and HCN[J]. Biosensors and Bioeleetronics, 1990, 5(5): 397-413.
  • 2Almestrand L, Betti M, Hua C, et al. Determination of lead in whole blood with a simple flow - injection system and computerized strippingpotentiometry[J]. Analytica Chimica Acta, 1988, 209:339 ~ 343.
  • 3徐云斌,许风华,张启生.石墨炉全自动原子吸收法测定血铅[J].中国公共卫生,2004,20(10):1158-1158. 被引量:4
  • 4Botre C, Botre F, Jommi G, et al. Synthesis and inhibitory activity on carbonic anhydrase of some new sulpiride analogs studied by means of a new method [ J ].Journal of Medicinal Chemistry, 1986, 29(10): 1 814 ~1 820.
  • 5Fair B D, Jamieson A M. Studies of protein adsorption on polystyrene latex surfaces [ J ]. Journal of Colloid and Interface Science, 1980, 77(2): 525 ~ 534.
  • 6Guilbauh G G, Brignac P Jr, Zimmer M. Homovanillic acid as a fluorometric substrate for oxidative enzymes.Analytical applications of the peroxidase, glucose oxidase, and xanthine oxidase systems[J]. Analytical Chemistry, 1968, 40(1): 190 ~ 196.
  • 7王伟,黄福模,吴小平,徐健.消化血铅的微分电位溶出分析法[J].中国职业医学,2002,29(6):39-40. 被引量:4
  • 8Matson. Testing reagent[P]. United States Patent:4374041, Feberary 15, 1983.

二级参考文献3

  • 1李盛亮.原子吸收光谱法[M].上海:科学技术出版社,1989..
  • 2中华人民共和国卫生部. 血中铅的微分电位溶出测定方法[M]. 北京:中国标准出版社,1997. 1.
  • 3傅晖蓉,黄盈煜.血铅的同位镀汞微分电位溶出测定[J].中国职业医学,2000,27(4):39-39. 被引量:4

共引文献6

同被引文献20

引证文献1

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部