摘要 2006年11月4日,西欧8个国家发生了欧洲30年来最严重的停电事故,欧洲输电协调联盟(UCTE)和德国E.ON公司先后公布了事故调查分析报告。文中简要介绍了大停电基本情况,然后对事故报告进行了讨论分析,提出了增强电网运行管理的措施。最后指出电网动态监控系统的开发和应用有助于预防连锁故障、提高运行可靠性。 On November 4, 2006, a large scope blackout was occurred in 8 countries of Western Europe, which is the most serious failure in Europe in the recent 30 years. Union for the Co-ordination of Transmission of Electricity (UCTE) and E. ON Corporation released their reports of investigations successively. This paper introduces the case and its analysis of "11·4" blackout, and discusses these reports, brings forward some methods to strengthen operation. At last, it is indicated that developing and application of dynamic SCADA system will be valid to avoid cascading failure and improve operation reliability.