摘要 目的:测定100g/L构橼酸钾溶液的含量。方法:采用pH指示剂吸光度比值法,以0.5/L麝香草酚蓝醇溶液为指示剂,0.5mo1/L盐醚为标准液,测定波长为435nm和551nm。结果:线性关系良好,r=0.9998(n=5),平均回收率为99.02%(n=5),RSD=0.87%。经与中和法比较,表明其测定结果与本法无显著性差异(P>0.05)。结论:本法准确度高,简便,快速,适用于医院制剂分析。 OBJECTIVE :To make an assay,a pH-indicator absorbance radio method was established for l00 g/LLiquor Kalii citrtis,METHOD:A pH-indicator absorbance radio method was used,0.5/L solution of thymol bluewas used as indicator and 0.5 mol/L hydrochloric acid solution as volumetric solution.The absorbance was mea-sured at 435 nm and 551 nm.RESULTs:The calobration curve was linear(r=0.999 8,n=5).The average recoveryfor the assay was 99. 02 with relative standard deviation of 0.87%(n=5).The resuIts obtained by using pH-indica-tor absorbance radio method and neutralization method respectively were not statistically significant(P> 0.05)CONCLUSION:The method is simple,rapid and suitable for analysis in hospital.
作者 赵志英
出处 《中国药学杂志》 CAS CSCD 北大核心 1996年第12期749-751,共3页 Chinese Pharmaceutical Journal
关键词 pH指示剂 吸光度比值法 枸橼酸钾 麝香草酚蓝 pH-indicator absorbance radio method,kalii citritis,Thymol blue