磁阀式可控并联电抗器模型试验研究 被引量:7

Test of magnetic valve controllable parallel reactor model
下载PDF
导出
摘要 介绍了磁阀式可控电抗器的工作原理和结构特点,制作了磁阀式可控电抗器模型,并对模型的空载损耗、伏安特性、谐波特性、控制特性、响应时间等性能进行了试验研究,通过对比分析试验数据和理论计算结果,采用模型试验技术对50 Mvar/500 kV磁阀式可控并联电抗器的特性进行研究,为确定50 Mvar/500 kV电抗器原型结构和优化设计提供了可靠的试验参考依据。试验结果表明:所设计的磁阀式可控电抗器模型具有谐波小、损耗低及良好的动态性能;同时表明模型试验技术是一种成本低、效率高的特性分析方法。 The principle and structure of magnetic valve controllable reactor are introduced. The reactor model is set and its performance is tested,such as no-load loss,volt-ampere characteristics, harmonic characteristics,control characteristics and response time. By comparing test resuhs and theoretical calculation,characteristics of a 50 Mvar/500 kV magnetic valve controllable parallel reactor is studied,which provides reliable test reference data for its optimum structure design. Test results show that,the designed reactor model has small harmonics,low losses and good dynamic performance,and the model test is an efficient and low-cost method of characteristic analysis.
出处 《电力自动化设备》 EI CSCD 北大核心 2007年第1期68-71,共4页 Electric Power Automation Equipment
关键词 可控电抗器 磁阀 并联电抗器 controllable reactor magnetic valve parallel reactor
  • 相关文献

参考文献10

二级参考文献15

  • 1Chen B C, Kokemak J M. Thyristor controlled twostage magnetic-valve reactor for dynamic var-compensation[C]. Proceedings of IEEE-APEC, 2000.2,1066-1072.
  • 2尹忠东,高电压技术,1996年,3期
  • 3蔡旭,电力系统自动化,1995年,19卷,8期
  • 4尹忠东,94’全国青年电力系统学术会议论文集,1994年,10页
  • 5李福寿,中性点非有效接地电网的运行,1993年,10页
  • 6THE米勒 胡国根.电力系统无功功率控制[M].北京:水利电力出版社,1990..
  • 7山西省电力工业局编.继电保护[M].北京∶中国电力出版社,2000..
  • 8周敦锋.电工调试[M].北京∶中国建筑工业出版社,1995..
  • 9陈柏超,陈维贤,尹忠东,刘益慧.10 kV 电网新型自动调谐消弧线圈及控制装置[J].中国电力,1997,30(9):70-71. 被引量:26
  • 10刘虹,尹忠东,陈柏超,陈维贤.新型可控自动消弧成套装置的应用研究[J].农村电气化,1998(4):25-26. 被引量:8

共引文献150

同被引文献58

引证文献7

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部