期刊文献+

流动注射化学发光法测定氨基乙酸的研究 被引量:4

A Study of Determination of Amino Acetic Acid with Flow-injection Chemiluminescence Method
下载PDF
导出
摘要 实验研究了影响化学发光信号强度值的各种因素,初步探讨了体系产生化学发光的可能机理。在优化的实验条件下,氨基乙酸在1.0×10^-7~1.0×10^-4kg·L^-1的质量浓度范围内与化学发光信号强度呈良好的线性关亲.检出限(3σ)为3×10^-8~kg·L^-1。对质量浓度为1.0×10^-6kg·L^-1的氨基乙酸溶液连续测定11次。相对标准偏差(RSD)为2.8%,将该方法用于氨基乙酸模拟样品的分析,结果满意。 The new method for the determination of Amino acetic acid with flow injection chemiluminescence is here described. It is based on the chemiluminescence during the oxidation of Amino acetic acid by N-bromosuccinimide in alkaline medium in the presence of dichlorofluorescein as energy transfer. Various factors influencing the chemiluminescence system are studied thoroughly and a preliminary discussion on the mechanism of the CL reaction is also given. The linear range for Amino acetic acid is 1.0 × 10 ^-7 - 1.0 × 10^-4 kg · L^-1 with the relative standard deviation of 2.8% ( C = 1.0 × 10 ^-6 kg · L^-1 ,n = 11 ). Under the optimum conditions. The detection limit (3σ) is 3 × 10^-8 kg · L^-1, the recommended method has been successfully used for the analysis of Amino acetic acid of simulation sample.
出处 《重庆师范大学学报(自然科学版)》 CAS 2007年第1期62-65,共4页 Journal of Chongqing Normal University:Natural Science
基金 第二批"重庆市高等学校优秀中青年骨干教师资助计划"[渝教人(2005)2号]
关键词 N-澳代琥珀酰亚胺 二氯荧光素 氨基乙酸 流动注射 化学发光 N-bromosuccinimide dichlornfluorescein Amino acetic acid flow injection chemiluminescence