期刊文献+

针刺热电池无电压输出原因分析及其改进 被引量:1

Improvement and Analysis of Stab Thermal Battery with Non Voltage Output
下载PDF
导出
摘要 针对针刺热电池无电压输出的问题,建立了故障树,进行原因分析和验证试验。查找出现故障的主要原因为隔板与挡板之间空隙小以及火帽表面有异物,并采取相应的解决措施,验证试验表明故障原因定位准确,解决措施有效。 Aimed at the problem of stab thermal battery with no voltage output, the fault tree analysis was founded, and the reason was analyzed and verified. It showed that the main reasons of the fault were small void between bulkhead and fender, and some substance covered on the appearance of stab primer. The verified test result indicated that the reasons of fault were correct, and the improvement was effect.
出处 《火工品》 CAS CSCD 北大核心 2006年第6期32-34,共3页 Initiators & Pyrotechnics
关键词 针刺热电池 无电压输出 原因分析 改进 Stab thermal battery Non voltage output Reason analysis Improvement
  • 相关文献

参考文献1

二级参考文献4

  • 1[2]劳允亮.起爆药化学与工艺学[M].北京理工大学出版社,1999.
  • 2[3]李桂茗.火工品[M].南京理工大学出版社,1996.
  • 3[4]北京工业学院841教研室.起爆药[M].北京工业学院,1975.
  • 4袁有根,刘成生,李文.小型针刺延期雷管延期精度的研究[J].火工品,2004(1):17-18. 被引量:7

共引文献6

同被引文献11

  • 1颜洪璋.某小型针刺雷管瞎火原因分析及解决[J].火工品,2005(5):39-41. 被引量:7
  • 2刘占辰.热电池激活时间研究[J].火工品,2006(6):28-31. 被引量:12
  • 3引信设计手册[M].北京:国防工业出版社,2005.
  • 4Bush D M. A Pellet-Type Thermal Battery[P]. US: SAND-74-007,1974.
  • 5Guidotti R A. A Mimiature Shock-Activated Thermal Battery for Munition Applications [P]. US: SAND-98- 0940c, 1998.
  • 6Van Domelen B H, Wehrle R D. A Review of Thermal Battery Technology[P]. US: SLA-74-5381,1974.
  • 7Bush D M. A Sixty Minute Thermal Battery[P]. US: SAND-75-0454,1975.
  • 8Bush D M. Development of Lithiun Alloy/Disufide 60 Minute Primary Thermal Battery[P]. US.. Sand-79-0814, 1979.
  • 9Bush D M. Baldwin A R. A Preliminary Study into the Feasibility of a Sixty-Minute thermal Battery-P3. US: SLA-73-042A, 1973.
  • 10赵广波,徐莹,汴纪庆,张承伟,陈东林.热电池技术进展及在引信中的应用[J].探测与控制学报,2008,30(6):64-68. 被引量:11