期刊文献+

ICI探测器单位γ灵敏度研究 被引量:2

The sensitivity response of ICI detector for γ-ray
下载PDF
导出
摘要 探测器灵敏度及其能量响应特性在探测器的设计和研制过程中占有十分重要的地位。从理论和实验两个方面研究了ICI探测器的γ灵敏度及其γ射线能量响应特性。在^60Co1.25MeV γ辐射源装置上进行实验测量得到ICI探测器的单位γ灵敏度为I.8×10^20(±5%)C·cm^2,理论计算的单位γ灵敏度为1.78×10^-29C·cm^2(γ能量1.25MeV),理论和实验结果符合得较好。研究结果表明,入射γ射线能量在1-10MeV范围内变化时,ICI探测器具有平坦的γ灵敏度响应曲线。 The energy response of a new-type gamma-ray detector, which is called ICI (Insulator-Conductor-Insulator) detector, has been investigated using Monte-Carlo code and experimental method. The theoretical calculation sensitivity of the ICI detector is 1.78 × 10^-20C · cm^2/γ (at 1.25MeV T-ray). The sensitivity obtained by experiment is 1.8 × 10^-20( ± 5%) C ·cm^2/γ. The calculation results are in good agreement with experimental data. It is shown that the ICI detector slmost has the same sensitivity of γ- ray energy ranging between 1MeV and 10MeV.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2007年第1期5-7,共3页 Nuclear Electronics & Detection Technology
关键词 ICI探测器 Γ射线 脉冲辐射探测 ICI detector gamma-ray pulsed radiation detection
  • 相关文献

参考文献7

  • 1欧阳晓平,张忠兵,王群书,王伟.用于脉冲n/γ混合场γ强度测量的ICI探测器[J].高能物理与核物理,2006,30(3):228-231. 被引量:6
  • 2Ebert P J,et al.Vacuum Diode Detector for Measuring High Intensity Gamma-Ray Flux[J].Rev Sci Instrum,1967,38(12):1747.
  • 3Knoll GF.Radition Detection and Measurement[M].New York:John Wiley &Sons,Inc.,2000.
  • 4Fewell TR.Compton Diodes:Theory and Development for Radiation Detectors,SC-DR-720118,1972.
  • 5倪源兴.脉冲射线测量和诊断技术[M].西安:西北核技术研究所,1997.
  • 6Briesmeister J B.MCNP-A general Monte Carla n-particle transport code[R].LA-12625-M-manual,1997.
  • 7马彦良.狭缝式高灵敏度裂变中子探测系统γ灵敏度研究[D].西安:西北核技术研究所,2005:52-53.

二级参考文献12

  • 1欧阳晓平,李真富,王群书,霍裕昆.用于强γ环境中测量中子参数的薄膜塑料闪烁探测器(英文)[J].高能物理与核物理,2005,29(4):399-403. 被引量:12
  • 2欧阳晓平,李真富,王群书,霍裕昆,马彦良,张前美,张国光,金玉仁.狭缝式高灵敏裂变中子探测系统[J].物理学报,2005,54(10):4643-4647. 被引量:16
  • 3刘兆庆等.脉冲辐射场诊断技术.北京:科学出版社,1994.186-196.
  • 4倪源兴.脉冲射线测量和诊断技术.西安:西北核技术研究所,1997.64-77.
  • 5Ebert P J,Lauzon A F.Vacuum Diode Detector for Measuring High Intensity Gamma-Ray Flux.Rev.Sci.Instr.,1967,38(12):1747-1752.
  • 6Fewell T R.Compton Diodes:Theory and Development for Radiation Detectors:SC-DR-720118.1972.
  • 7Knoll G F.Radition Detection and Measurement[M].New York:John Wiley & Sons,Inc.,2000.
  • 8Stevens J.Design and Characterization of an Absolute Gamma-Ray Intensity Detection:EGG1183-2288.1972.
  • 9Artuso J,Stevens J.Linearity,Time Domain Reflector Meter and Fourier Analysis Studies of an Evacuated Compton Detector:EGG 1183-2277.1971.
  • 10Ebert P J,Lauzon A F.IEEE Trans.Nucl.Sci.,1966,NS13(2):735-741.

共引文献7

同被引文献15

  • 1吕铭方,韩,王新新.用银激活计数器测量快脉冲中子[J].核电子学与探测技术,1994,14(4):212-217. 被引量:10
  • 2马驰.宽量程中子探测靶室[J].核电子学与探测技术,1995,15(6):373-376. 被引量:4
  • 3胡孟春,陈法新,李忠宝,唐章奎,张三阳,唐正元,张建华.能量响应相对平坦的康普顿探测器[J].核电子学与探测技术,2005,25(6):668-670. 被引量:4
  • 4欧阳晓平,张忠兵,王群书,王伟.用于脉冲n/γ混合场γ强度测量的ICI探测器[J].高能物理与核物理,2006,30(3):228-231. 被引量:6
  • 5张传飞.探测中子用裂变伽马探测器设计技术总结报告[R].中国工程物理研究院核物理与化学研究所.
  • 6吕敏.脉冲辐射束测量技术.核电子学与探测技术,1984,4(6).
  • 7Ebert Paul J..A Survey of Nuclear-Explosive Prompt Diagnostics[R].UCRL-53724.
  • 8张建华.裂变伽马探测器的设计及应用总结报告[R].中国工程物理研究院核物理与化学研究所.
  • 9Ebert P.J.and Lauzon A.F..Vacuum Diode Detector for Measuring High Intensity Gamma-Ray Flux[J].Review of Scientific Instrument,1967,38(12):1747-1752.
  • 10Briesmeister J.F.MCNP-A General Monte Carlo N-Particle Transport Code,Version 4B,LA-12625-M,1997:3-63.