R410A变频涡旋房间空调器的仿真研究 被引量:3

Simulation Study on Inverter Scroll Room Air-Conditioner Using Refrigerant R410A
下载PDF
导出
摘要 目前房间空调器仿真压缩机模型国内外一般为滚动转子式压缩机,本文模型对象为R410A直流变频涡旋压缩机、冷凝器为整体平翅片、蒸发器为双面开缝翅片、节流装置采用毛细管。并对模型进行了实验验证,制冷量、功率和能效比的相对误差分别为2.855%、6.223%、3.892%。 The current simulation models of compressor in room air-conditioner are usually for the rotary compressors both in overseas and domestic. In this paper, a scroll compressor with DC-inverter, a condenser with whole plain-fins, an evaporator with double-face slotted fins and a capillary tube as a throttle device are used. The simulation results are validated by experiment, the respective relative errors of refrigeration capacity, power and COP are 2.885%, 6.223%, 3.892%.
出处 《家电科技》 2007年第2期53-54,共2页 Journal of Appliance Science & Technology
关键词 房问空调器 R410A 直流变频 涡旋压缩机 Room air-conditioner,R410A,DC-inverter,Scroll compressor
  • 相关文献

参考文献4

  • 1周宏坤,俞诚民.浅谈直流变频空调器的工作原理[J].电机电器技术,2000(1):25-28. 被引量:7
  • 2S.J,Eckels. Evaporation and Condensation of HCF-134a and CFC-12 in a Smooth Tube and a Micro-fm Tube[J].ASHRAE Trans, 1991, Vol.97, part 2: 71-81.
  • 3Samuel M.Sami, P.J.Tulej, B.Song. Study of Heat and Mass Characteristics of Ternary Nonazeotropic Refrigerant Mixtures Inside Air/Refrigerant-Enhanced Surface Tubing[J].ASHRAE Trans .1995 .Vol.101: 1402-1412.
  • 4张乐平 文健 张早校 等.R410A变频空调系统的计算机模拟分析[J].流体机械,2002,30:200-204.