摘要
依据《夏热冬冷地区居住建筑节能设计标准》的相关规定,对D值达不到要求的架空平板通风屋顶进行隔热验算,得出其节能设计的直观标准,方便广大设计人员在实际工程中采用。
According to a rule In Design Standard for Energy Efficiency of Residential Buildings In Hot Summer and Cold Winter Zone, we conduct a heat insulation test for aerial slab ventilation roofs of which Index of thermal Inertia Is under the standard, to reach a more practical benchmark for designers to apply in projects.
出处
《华中建筑》
2006年第9期34-36,共3页
Huazhong Architecture
关键词
夏热冬冷地区居住建筑节能设计标准
D值
架空平板通风屋顶
Design Standard for Energy Efficiency of Residential Buildings In Hot Summer and Cold Winter Zone, Aerial slab ventilation roof with D thermal inertia