摘要
分析了某电厂2台25 MW汽轮机高压加热器运行故障发生的原因,提出了相应的技术改造措施。高加系统和疏水器改造后,运行正常,机组安全可靠性和经济性提高。
The causes leading to troubles in operation of the high - pressure heater in one power plant have been analysed, and corresponding measures for technical retrofit being put forward. After retrofitting the high - pressure heater system and drain trap, the operation is normal, enhancing the safety, reliability and economic behavior of the u-nit.
出处
《热力发电》
CAS
北大核心
2006年第12期39-40,共2页
Thermal Power Generation