期刊文献+

600MW机组锅炉分隔屏过热器变工况壁温分析 被引量:2

ANAMSIS OF TUBE-WALL TEMPERATURE FOR SUPERHEATER WITH DIVIDING PANEL UNDER OFF -DESIGN CONDI-TION OF 600 MW UNIT'S BOILER
下载PDF
导出
摘要 通过对600 MW机组四角切圆燃烧锅炉的前屏过热嚣在BMCR、BRL(不投油最大稳燃负荷)、100%ECR、滑压75%、滑压50%、高压加热器切除6种典型工况的三维壁温计算,得到了各工况下前屏过热器典型三维壁温分布及最高壁温高发生的部位和最高壁温值。根据分隔屏过热器的壁温计算结果,对过热器的设计和选材提出了优化设计方案。 Through three-dimensional tube - wall temperature calculation of the front panel superheater for a tangential firing boiler of 600 MW unit under six operating con-ditions,namely BMCR,BRL, 100 % ECR, 75 % sliding pressure. 50 % sliding pressure, and cut - off of the high - pressure beater, a typical three - dimensional tube - wall temperature distribution of the front panel superheater, and positions at which the highest tube - wall temperature being occurred, as well as values of the highent tube - wall temperature under various operating conditions have been obtained. Based on results of calculating the tubewall temperature of the superheater with dividing panel,a optimi-zing design scheme has been put forward for designing the superheater and selecting the materials used.
出处 《热力发电》 CAS 北大核心 2006年第12期64-66,共3页 Thermal Power Generation
关键词 锅炉 四角切圆燃烧 分隔屏过热器 热偏差 三维壁温计算 boiler tangential firing superheater with dividing panel thermal deviation three dimensional tube-wall temperature calculation
  • 相关文献

参考文献5

  • 1余艳芝,唐必光,李树雷.高温过热器壁温测试及计算[J].热能动力工程,2003,18(1):71-73. 被引量:10
  • 2付强,余艳芝,王志民,陶承志.330MW旋流对冲锅炉分隔屏过热器三维壁温计算[J].电站系统工程,2005,21(2):23-24. 被引量:4
  • 3(苏)洛克申,等.锅炉机组水力计算(标准方法)[M].董祖康等译.北京:电力工业出版社,1981.
  • 4Yu Yanzhi,Tang Biguang.The faults diagnosis and expert system of boiler superheater[C].Proceedings of the International Conference (ICECA'2001),2001.
  • 5Tang Biguang,Yu Yanzhi.Tube-wall temperature threedimensional distribution calculation of high-temperature superheater[C].Proceedings of the International Conference (ICECA'2001),2001.

二级参考文献5

共引文献10

同被引文献16

引证文献2

二级引证文献4