期刊文献+

First large scale application of novel Si stripixel detector in real large experiment: Si VTX in PHENIX upgrade at RHIC

First large scale application of novel Si stripixel detector in real large experiment: Si VTX in PHENIX upgrade at RHIC
下载PDF
导出
摘要 2D position sensitive, single-sided Si stripixel detector was selected as the one of the two main components of the Si vertex tracker (Si SVX) in the upgraded PHENIX detector at RHIC (relativistic heavy ion collider) in Brookhaven National Laboratory (BNL). This is the first large scale application of the novel Si stripixel detector in a real large experiment after many years of research and development at BNL. The first and second prototype fabrication runs of the SVX stripixel detectors were carried out successfully in BNL’s Si detector development and processing Lab. The processing of these stripixel detectors is similar to that for the standard single-sided strip detectors: one-sided processing, single implant for the pixel (strip) electrodes, etc. The only additional processing step is the double metal process, a technology that is simple and well matured by many Si detector processing industries and labs, including BNL. The laser and beam tests on those prototype detectors show the 2D position sensitivity and good position resolution in both X and U coordinates (about 25 μm for 80 μm pitch). For the mass production of 400 sensors needed for the Si SVX, the processing technology has been successfully transferred to the industrial: Hamamatsu Photonics (HPK). HPK has produced a pre-production run of stripixel sensors with the full PHENIX SVX specification on 150 mm diameter wafers. The laser tests on these pre-production wafers show good signal to noise ratio (about 20∶1). 2D position sensitive, single-sided Si stripixel detector was selected as the one of the two main components of the Si vertex tracker (Si SVX) in the upgraded PHENIX detector at RHIC (relativistic heavy ion collider) in Brookhaven National Laboratory (BNL). This is the first large scale application of the novel Si stripixel detector in a real large experiment after many years of research and development at BNL. The first and second prototype fabrication runs of the SVX stripixel detectors were carried out successfully in BNL's Si detector development and processing Lab. The processing of these stripixel detectors is similar to that for the standard single-sided strip detectors: one-sided processing, single implant for the pixel (strip) electrodes, etc. The only additional processing step is the double metal process, a technology that is simple and well matured by many Si detector processing industries and labs, including BNL. The laser and beam tests on those prototype detectors show the 2D position sensitivity and good position resolution in bothXand U coordinates (about 25 μm for 80 μm pitch). For the mass production of 400 sensors needed for the Si SVX, the processing technology has been successfully transferred to the industrial: Hamamatsu Photonics (HPK). HPK has produced a pre-production run of stripixel sensors with the full PHENIX SVX specification on 150 mm diameter wafers. The laser tests on these pre-production wafers show good signal to noise ratio (about 20 : 1).
出处 《中国有色金属学会会刊:英文版》 CSCD 2006年第B01期141-145,共5页 Transactions of Nonferrous Metals Society of China
基金 Project(DE-Ac02-98CH10886) supported in part by the US Department of Energy
关键词 相对论性重离子碰撞 PHENIX探测器 天顶跟踪器 硅顶点探测器 硅条探测器 应用 Si strip detector Si stripixel detector vertex detector 2D Si detector 2D position sensitivity AC coupling
  • 相关文献

参考文献10

  • 1ADCOX K. PHENIX Collaboration. PHENIX detector overview[J]. Nucl Instr and Meth A, 2003, 499: 469-479.
  • 2CIANCOLO V. PHENIX SVX, silicon vertex upgrade for PHENIX, PHENIX Internal Note an180, 2003.
  • 3LI Z. Novel silicon stripixel detector: Concept, simulation, design, and fabrication [J]. Nucl Instr & Meth A, 2004, 518: 738-753.
  • 4LI Z, EN'YO H, GOTO T, RADEKA V, CHEN W, ELLIOTT D, KAWABATA T, TOGAWA M, SAITO N, RYKOV V, TANIDA K, TOJO J. Novel silicon stripixel detector for PHENIX upgrade [J]. Nucl Instr and Meth A, 2004, 518: 300-304.
  • 5LI Z, EN'YO H, GOTO T, RADEKA V, CHEN W, ELLIOTT D,KAWABATA T, TOGAWA M, SAITO N, RYKOV V, TANIDA K,TOJO J. Development of 2 prototype of novel silicon stripixeldetector for phenix upgrade [J]. Nucl Instr and Meth A, 2004, 535:404-409.
  • 6TOJO J, AOKI K, EN'YO H, FUKAO Y, GOTO Y, HEUSER J M,LI Z, OHNISHI H, OKADA H, RADEKA V, RYKOV V L, SAITO N, SAKUMA E SEKIMOTO M, TANIDA K, TOGAWA M,WATANABE Y. Development of a novel silicon stripixel detector for RHIC-PHENIX detector upgrade [J]. IEEE Trans Nucl Sci, 2004, 51 :2337.
  • 7KISTENEV E, LI Z, MERKINE M, SETO R, SUKHANOV A, VRBA V. Silicon sensors for the forward calorimeters for the PHENIX experiment at RHIC [A]. IEEE Nucl Sci Symp[C].Puerto Rico: IEEE Trans Nucl Sci,2005.
  • 8CHABAUD V, et al. Beam test results from a prototype for the delphi microvertex detector[J]. Nucl Instr and Meth A, 1990, 292: 75.
  • 9CMS Technical Proposal. CERN/LHCC/94-38, 1994.
  • 10ATLAS Technical Proposal. CERN/LHCC 94-43, 1994.