摘要
目的:研究RT-Q医用生物膜(以下简称RT-Q膜)的术中局部止血作用及其生物相容性。方法:通过比较RT-Q膜、瞬康医用胶(以下简称瞬康胶)、附加剂、阴性对照对大鼠颈外静脉切口出血时间和出血量的影响,研究其术中止血效果;通过观察大鼠后肢肌肉切开用此膜后对伤口愈合、生物膜降解及周围组织是否有毒性影响等情况评价其生物相容性。结果:与阴性对照组、附加剂组比较,RT-Q膜组止血效果显著(P〈0.01),与瞬康医用胶组比较无统计学意义;RT-Q膜对伤口愈合既无促进也无延迟性影响,形成的膜于术后15d开始降解,3~4周完全吸收,对周围组织无毒性影响。结论:RT-Q医用生物膜的局部止血效果显著、且具有生物相容性。
AIM: To investigate the hemostatic effect and biocompafibility of RT-Q-remedial biomembrane. METHODS: There were control, excipient, Shunkang and RT-Q group in topical bleeding experiment and control, excipient, and RT-Q group in topical biocompatibility experiment, in order to study the hemostatic effect on jugular vein of rat, and to observe the biodegradability and histocompatibility of RT-Q in muscle of rat legs. RESULTS: The hemostatic effect is significant compared with control group and excipient group (P 〈 0.01), but there is no significant difference compared with Shunkang group ( P 〉 0.05). The biological evaluation for the biocompatibility is excellent. CONCLUSION: The significant hemostatic effect and good biocompatibility have been proved in topical bleeding of RT-Q.
出处
《中国临床药理学与治疗学》
CAS
CSCD
2006年第12期1345-1349,共5页
Chinese Journal of Clinical Pharmacology and Therapeutics
基金
国家863计划资助课题(№2002AA326050)