期刊文献+

Density of liquid NiCoAlCr quartemary alloys measured by modified sessile drop method

Density of liquid NiCoAlCr quartemary alloys measured by modified sessile drop method
下载PDF
导出
摘要 The densities of liquid NiCoAlCr quaternary alloys with a fixed molar ratio of Ni to Co to Al (x(Ni):x(Co):x(Al)≈73:12.15) which is close to the average value of the commercial Ni-based superalloys TMS75, INCO713, CM247LC and CMSX-4, and the mass fraction of chromium changes from 0 to 9% were measured by a modified sessile drop method. It is found that with increasing temperature and chromium concentration in the alloys, the densities of the liquid NiCoAlCr quaternary alloys decrease, whereas the molar volume of the liquid NiCoAlCr quaternary alloys increases. And the liquid densities of NiCoAlCr quaternary alloys calculated from the partial molar volumes of nickel, cobalt, aluminum and chromium in the corresponding Ni-bases binary alloys are in good agreement with the experimental ones, i.e. within the error tolerance range the densities of the liquid Ni-based multi-component alloys can be predicted from the partial volumes of elements in Ni-based binary alloys in liquid state. The molar volume of liquid NiCoAlCr binary alloy shows a negative deviation from the ideal linear mixing and the deviation changes small with the increase of chromium concentration at the same temperature. The densities of liquid NiCoAlCr quaternary alloys with a fixed molar ratio of Ni to Co to Al (x(Ni):x(Co):x(Al)≈ 73:12:15) which is close to the average value of the commercial Ni-based superalloys TMS75, INCO713, CM247LC and CMSX-4, and the mass fraction of chromium changes from 0 to 9% were measured by a modified sessile drop method. It is found that with increasing temperature and chromium concentration in the alloys, the densities of the liquid NiCoAICr quaternary alloys decrease, whereas the molar volume of the liquid NiCoAICr quaternary alloys increases. And the liquid densities of NiCoAICr quaternary alloys calculated from the partial molar volumes of nickel, cobalt, aluminum and chromium in the corresponding Ni-bases binary alloys are in good agreement with the experimental ones, i.e. within the error tolerance range the densities of the liquid Ni-based multi-component alloys can be predicted from the partial volumes of elements in Ni-based binary alloys in liquid state. The molar volume of liquid NiCoAICr binary alloy shows a negative deviation from the ideal linear mixing and the deviation changes small with the increase of chromium concentration at the same temperature.
出处 《中国有色金属学会会刊:英文版》 CSCD 2006年第A03期1962-1966,共5页 Transactions of Nonferrous Metals Society of China
基金 Project(NCET-05-0764) supported by the Program for New Century Excellent Talent in University project(2004527) supported by SRF for ROCS, SEM
关键词 钴合金 有色金属 液相 抗热性 NiCoAlCr alloy liquid density liquid state sessile drop method molar volume
  • 相关文献

参考文献7

二级参考文献52

  • 1LiangFANG,ZushuLI,ZaiNanTAO,FengXIAO.Density of Liquid Ni-Mo Alloys Measured by a Modified Sessile Drop Method[J].Journal of Materials Science & Technology,2004,20(3):287-292. 被引量:4
  • 2方亮,肖锋,陶再南,汪立文,向井楠宏.用改良密度法精密测量熔融Ni-Ta二元合金的液态密度(英文)[J].稀有金属材料与工程,2005,34(4):521-525. 被引量:6
  • 3[1]V.N.Eremenko and Y.V.Naidich: Fiz. Met. i Metalloved, 1961,11, 6.
  • 4[2]M.Kato, S.Ikuta, K.Hisada and J.Hasegawa: Reports of the Government Industrial Research Institute, Nagoya, 1987, 36,152.
  • 5[3]K.Mukai, H.Sakao and K.Sano: J. Japan Inst. Metals, 1967,31, 928.
  • 6[4]Z.Yu and K.Mukai: J. Japan Inst. Metals, 1995, 59, 806.
  • 7[5]K.Mukai and F.Xiao: Mater. Trans., 2002, 43, 1153.
  • 8[6]D.J.Steinberg: Metall. Trans., 1974, 5A, 1341.
  • 9[7]E.S.Levin and G.D.Ayushina: Russ. J. Phys. Chem., 1971,45, 792.
  • 10[8]G.Scatchard: Trans. FaradaySoc.,1937,99,160.

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部