期刊文献+

激光测高系统中基于GP1的飞行时间测量 被引量:2

Time-of-flight measurements with TDC-GPI in laser.altimeter
下载PDF
导出
摘要 激光测高仪是测量激光脉冲的飞行时间来获得测高仪与探测目标之间的距离,因此激光飞行时间测量的准确性是衡量其系统能力的根本指标.采用了一种专用的时间数字转换芯片设计了时间间隔测量模块,它采用延时线技术,测量频率快,时间分辨率高,受外界环境干扰小,完全适合激光测高的要求.在给出软硬件实现方法的同时,也给出了测量结果. Pulsed time-of-flight laser altimeter operates by transmitting a short laser pulse to an optical visible target and by detecting the reflected pulse with an optical detector. The measured distance is calculated from this flight time. So the accuracy of laser time interval is a basic beacon to measure its system capability. We use a special time-digit.al-converter chip to develop a high resolution time interval module. Based on delay chain; it has high frequency and precision, suffer no outside environmental interference, completely suite for laser altimeter. Finally the soft and hardware realization method and measurement result are given.
出处 《量子电子学报》 CAS CSCD 北大核心 2007年第1期96-99,共4页 Chinese Journal of Quantum Electronics
关键词 光电子学 激光测高 时间间隔测量 延时线 optoelectronics laser altimetry time interval measurement delay chain
  • 相关文献

参考文献6

  • 1Kalisz J.Review of methods for time interval measurements with picosecond resolution[J].Institute of Physics Metrologia,2004,41:17-32.
  • 2ACAM corporation.TDC-GP1 Functional Description[Z].Germany:2001.
  • 3Nutt R.Digital time intervals meter[J].Rev.Sci.Instrum.,1968,39:1342-5.
  • 4Maatta K,Kostamovaara J.A high-precision time-to-digital converter for pulsed time-of-flight laser radar applications[J].IEEE Transactions on Instrumentation and Measurement,1998,47(2).
  • 5Kalisz J,Pelka R,Poniecki A.Precision time counter for laser ranging to satellites[J].Rev.Sci.Instrum.,1994,65(3):736-741.
  • 6毕云峰,陈结祥,张毅,戚俊,涂碧海,赵平建.大气传输介质引起的激光测高仪回波能量衰减分析[J].量子电子学报,2005,22(6):918-922. 被引量:4