期刊文献+

辐射能信号与锅炉吸热量静态关系的试验分析

TEST STUDY ON STATIC RELATIONSHIP BETWEEN RADIANT ENERGY SIGNAL AND ABSORBED HEAT IN A BOILER
下载PDF
导出
摘要 通过三维温度场监控系统采集某300MW机组燃煤锅炉燃烧火焰图像,计算得到炉膛燃烧的辐射能信号,并根据锅炉运行参数计算了锅内过程不同阶段的吸热量。计算表明,除空气预热器外,在(200-300)MW负荷范围内,辐射能信号与锅炉不同阶段的吸热量均呈线性变化。把辐射能的微分信号引入到锅炉过热器的减温调节系统后,使过热蒸汽温度最大偏差〈3℃,取得了良好的实际调节控制效果。 The flame image of combustion in a boiler for 300 MW unit has been acquired through three dimentional temperature field monitoring system, and the radiant energy signal of combustion in the furnace being obtained from calculation, and the absorbed heat in different stages of process in the boiler being calculated on the basis of boiler operation parameters. The calculation shows that the radiant energy signal and the absorbed heat in different stages of process in the boiler all to be linear variation in the range of load 200-300 MW, not including the air preheater. After introducing differential signal of radiant energy into desuperheating system of the superheater, the maximal deviation of superheated steam temperature is〈3℃, abtaining good effectiveness in practical control.
机构地区 华中科技大学
出处 《热力发电》 CAS 北大核心 2007年第1期24-28,共5页 Thermal Power Generation
关键词 300 MW机组 锅炉燃烧 辐射能 吸热量 图像处理 300 MW unit combustion in boiler, radiant energy, absorbed heat image processing
  • 相关文献

参考文献3

二级参考文献16

  • 1娄春,韩曙东,刘浩,周怀春.一种煤粉燃烧火焰辐射成像新模型[J].工程热物理学报,2002,23(S1):93-96. 被引量:22
  • 2吴吕斌,罗自学,杨超,周怀春.300MW锅炉燃烧三维温度场可视化监测系统设计及运行分析[J].中国电力,2004,37(10):62-65. 被引量:13
  • 3周怀春,娄新生,肖教芳,尹鹤龄,邓元凯,顾一之,徐方灵,孙国俊.炉膛火焰温度场图象处理试验研究[J].中国电机工程学报,1995,15(5):295-300. 被引量:117
  • 4周怀春,娄新生,邓元凯.基于辐射图象处理的炉膛燃烧三维温度分布检测原理及分析[J].中国电机工程学报,1997,17(1):1-4. 被引量:50
  • 5Xiao X, Choi CW, Puri IK. Temperature Measurements in Steady Two-Dimensional Partially Premixed Flames Using Laser Interferemetric Holography. Combustion and Flame 1999, 120:318-332
  • 6Ohtake K, Okazaki K. Optical CT Measurement and Mathematical Prediction of Multi-Temperature in Pulverized Coal Combustion Field. Intl. J. Heat Mass Transfer, 1988, 31:397-405
  • 7Zhou HC, Han SD, Sheng F, et al. Visualization of ThreeDimensional Temperature Distributions in a Large-Scale Furnace Via Regularized Reconstruction from Radiative Energy Images: Numerical Studies, Journal of Quantitative Spectroscopy and Radiative Transf
  • 8Zhou HC, Sheng F, Han SD, et al. Reconstruction of Temperature Distribution in a 2-D Absorbing-Emitting System from Radiant Energy Images. JSME International Journal, Series B, 2000, 43(1): 104-109
  • 9Zhou HC, Han SD, Sheng F, et al. Visualization of threedimensional temperature distributions in a large-scale furnace via regularized reconstruction from radiative energy images:numerical studies [ J ]. Journal of Quantitative Spectroscopy and Radiative Transfer. 2002, 72,361~383.
  • 10Zhou HC, Zhang S S, Huang YL, Zheng CG. Monitoring of 2-D combustion temperature images in a 670t/h utility boiler and simulation on its application in combustion control [J].Dev. Chem. Eng. Mineral Process. 2000,8(3/4):311-322.