期刊文献+

300MW机组高压加热器泄漏原因分析和对策 被引量:1

CAUSE ANALYSIS OF HIGH-PRESSURE HEATER LEAKAGE FOR 300MW UNIT AND COUNTERMEASURES THEREOF
下载PDF
导出
摘要 高压加热器的运行性能和可靠性直接影响机组的经济性及安全性。平凉电厂2号机组3号高压加热器因运行中多次发生泄漏而频繁更换管束。通过对疏水调节系统和运行水位进行分析,查明高压加热器泄漏产生的原因,并给出了预防管束泄漏所采取的措施。 The operational performance and reliability of high- pressure heater directly affects the economic behavior and safety of unit. The leakage troubles have occurred many times on high - pressure heater no. 3 of unit no. 2 in Pinliang Power Plant, the tube - bundles being freguently replaced. Through analysis of the drain-regulating valve and the water-level in operation, the causes resuiting in leakages of the high -pressure heater have been found out, and measures adopted for preventing tube- bundle leakage being presented.
作者 曹枝阳
出处 《热力发电》 CAS 北大核心 2007年第1期54-57,共4页 Thermal Power Generation
关键词 300 MW机组 高压加热器 泄漏 汽水两相流 疏水调节系统 运行水位 300 MW unit high - pressure heater leakage steam - water two - phase flow drain - regulating system water - level in operation