摘要
采用节流装置配差压显示仪表测量脱硫富液流量时,由于节流装置存在量程小、阻力损失大和易堵塞等缺点,难以保证脱硫装置的正常运行,电磁流量计能较好地解决上述问题,生产实践表明,该仪表的性能稳定,运行可靠。
When the flowrate of desulphurized rich solution is measured with throttle device and differential pressure indicator, it is difficult to guarantee the normal operation of desulphrizing plant, because of several disadvantages such as, small measuring range, big loss resistance, easy blocking and so on. An electromagnetic flowmeter can be used well for the above-mentioned applicatian. Production practice proves that the meter has stable perfor- mance and operating reliability.
出处
《燃料与化工》
1996年第6期320-323,共4页
Fuel & Chemical Processes
关键词
脱硫
炼焦
煤气
脱硫
电磁流量计
Desulphurized rich solution—Flowrate
Electromagnetic flowmeter—Application