期刊文献+

Neurochip Based on Light-addressable Potentiometric Sensor

Neurochip Based on Light-addressable Potentiometric Sensor
下载PDF
导出
摘要 <正>A novel neurochip based on light addressable potentiometric sensor (LAPS) is designed.Using its light addressable characteristic.The problems of the limitations of restricted discrete active sites of current neurochips,such as microelectrode array and field effect transistor array can be settled easily.Based on the theoretical analysis of the interface between cells and LAPS,spontaneously discharges of hippocampal neurons induced by Mg~ 2+)-free media treatment were recorded by LAPS.The results demonstrate that this kind of neurochip has potential to monitor electrophysiology of cultured cells in a non-invasive way. A novel neurochip based on light addressable potentiometric sensor (LAPS) is designed. Using its light addressable characteristic. The problems of the limitations of restricted discrete active sites of current neurochips, such as microelectrode array and field effect transistor array can be settled easily. Based on the theoretical analysis of the interface between cells and LAPS, spontaneously discharges of hippocampal neurons induced by Mg^2+-free media treatment were recorded by LAPS. The results demonstrate that this kind of neurochip has potential to monitor electrophysiology of cultured cells in a non-invasive way.
出处 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期413-416,共4页 Rare Metal Materials and Engineering
基金 supported by the National Natural Science Foundation of China(Grant Nos.30270387,No.30570492) the Project of State Key Laboratory of Transducer Technology of China(Grant No.SKT0403) the Foundation for the Bureau of Zhejiang Province of China(Grant No.20040197).
关键词 NEUROCHIP cell-based biosensor hippocampal neurons light-addressable potentiometric sensor neurochip cell-based biosensor hippocampal neurons light-addressable potentiometric sensor
  • 相关文献

参考文献9

  • 1Michael P M, Jerome P, John W et al. J Neurosci Methods[J], 1999, 87:45.
  • 2Fromherz P. Physica E[J], 2003, 16:24.
  • 3Hafeman D G, Parce J W, McConnell H M. Science[J], 1988, 240:1182.
  • 4Ismail A B, Yoshinobu T, Iwasaki H et al. Biosens Bioelectron [J], 2003, 18:1509.
  • 5Stein B, George M, Gaub H E et al. Sensors Actuators B[J], 2004, 98:299.
  • 6Xu G X, Ye X S, Qin L F et al. Biosen Bioelectron[J], 2005, 20: 1757.
  • 7Fromherz P. Chem Phys Chem[J], 2002, 3:276.
  • 8Delorenzo R J, Pal S, Sombati S. Proc Natl Acad Sci USA[J], 1998, 95. 14482.
  • 9Zhang Q T, Wang P, Wolfgang J P et al. Sensors Actuators B [J], 2001, 73:299.