摘要
Hydrophobic polymer [ex.Poly(vinylidenfluoride)] layer was coated on polyaniline (PANi) sensor to reduce the problems of humidity.The differences in sensitivity to methanol gas detection in various humidity condition between pure-PANi sensor and coated with poly(vinylidenfluoride) polymer (PVDF) (coated-PANi sensor) were investigated.Also the relation between the density of pore,which was coated on the layer of the PANi sensor,and sensitivity was investigated.To fabricate the porous PVDF layer on PANi sensor,poly(vinylalcohol) (PVA),which is water-soluble polymer,was used. Coated-PANi sensor was less affected by humidity compared with pure-PANi sensor.And higher density of pore on PVDF layer led to higher sensitivity.
Hydrophobic polymer [ex. Poly(vinylidenfluoride)] layer was coated on polyaniline (PANi) sensor to reduce the problems of humidity. The differences in sensitivity to methanol gas detection in various humidity condition between pure-PANi sensor and coated with poly(vinylidenfluoride) polymer (PVDF) (coated-PANi sensor) were investigated. Also the relation between the density of pore, which was coated on the layer of the PANi sensor, and sensitivity was investigated. To fabricate the porous PVDF layer on PANi sensor, poly(vinylalcohol) (PVA), which is water-soluble polymer, was used. Coated-PANi sensor was less affected by humidity compared with pure-PANi sensor. And higher density of pore on PVDF layer led to higher sensitivity.
出处
《稀有金属材料与工程》
SCIE
EI
CAS
CSCD
北大核心
2006年第A03期459-462,共4页
Rare Metal Materials and Engineering