摘要
为表征SILEX-Ⅰ超强超短脉冲钛宝石激光装置的性能,利用高空间分辨的哈特曼波前传感器实验研究了该系统的光束波前畸变特性。实验中采用俄罗斯科学院激光和信息技术研究所研制的自缩束哈特曼波前测量系统,哈特曼波前传感器的最大入射口径可达95mm,测量精度为0.08μm。得到激光脉冲在压缩前的P-V值仅为0.13λ(λ=800nm),RMS值为0.02λ;压缩后P-V值为0.63,λRMS值为0.09λ,并对实验结果进行了分析和讨论。结果表明,该激光装置具有良好的光束质量,其主要波前畸变来源于压缩池。
To characterize beam quality in high power SILEX- Ⅰ ultra-short pulse Ti: sapphire laser system,experiments on wavefront measurement are performed. Using Shack-Hartmann wavefront sensor manufactured by Institute of Laser and Information Technology of the Russian Academy of Science, experiments at different positions are completed. The results show that the beam quality of this facility is very good,the P-V is 0.13λ,the RMS is 0.02λ before the compressor,and the P-V is 0.63A,the RMS is 0.09λ after the compressor. The experimental results show that the system has good beam quality, and the wavefront aberration mainly come from the compressor.
出处
《激光技术》
CAS
CSCD
北大核心
2007年第1期95-97,共3页
Laser Technology
关键词
激光技术
光束质量
波前测量
哈特曼波前传感器
高功率超短脉冲激光装置
laser technique
beam quality
wavefront measurement
Shack-Hartemann wavefront sensor
high power ultra- short pulse laser facility