摘要
采用混凝沉淀/曝气生物滤池一体式反应器对校园污水的再生回用处理进行了研究,考察了系统对SS、COD、NH3-N和TP的去除效果。结果表明:在混凝剂最佳投量为40 mg/L、沉淀池水力负荷为5 m3/(m2.h)的条件下,混凝沉淀对SS、COD和TP的平均去除率分别为67%、51.3%和73.3%;在COD和NH3-N的容积负荷分别为2.16 kgCOD/(m3.d)、1.07 kgNH3-N/(m3.d)的条件下,曝气生物滤池对SS、COD和NH3-N的平均去除率分别为95%、93%和94.5%。系统出水水质满足《城市污水再生利用城市杂用水水质》(GB/T18920—2002)标准的要求。
The integrated reactor of coagulation and sedimentation/BAF was used for school wastewater reclamation and reuse treatment. The removal efficiencies of SS, COD, NH3 - N and TP by the integrated reactor were investigated. The results show that under the conditions of optimal coagulant dosage of 40 mg/L and hydraulic loading of 5 m^3/( m^2 · h), the average removal rates of SS, COD and TP by coagulation and sedimentation are 67%, 51.3% and 73.3% respectively. When the volumetric loadings are 2.16 kgCOD/( m^3 · d) and 1.07 kgNH3 -N/( m^3 · d), the average removal rates of SS, COD and NH3 - N by BAF are 95 %, 93 % and 94.5 % respectively. The effluent quality meets the requirements of the Reuse of Urban Recycling Water-Water Quality Standard for Urban Miscellaneous Water Consumption ( GB/T 18920 - 2002).
出处
《中国给水排水》
CAS
CSCD
北大核心
2007年第3期74-77,共4页
China Water & Wastewater
基金
教育部鄱阳湖湖泊生态与生物资源利用重点实验室开放基金资助项目(PK2005015)
关键词
混凝沉淀
曝气生物滤池
污水处理
再生回用
coagulation and sedimentation
biological aerated filter (BAF)
wastewater treatment
reclaimation and reuse