摘要
通过对21例临床诊断主动脉瘤及主动脉夹层的患者进行西门子16排螺旋CT机(Siemens Somatom Sensation 16)平扫及增强扫描,并同时进行三维重建,以探讨主动脉病变的16排CT成像技术及其影像学表现特征。结果表明:(1)11例主动脉夹层中显示真假腔11例(100%)、内膜片11例(100%)、内膜破口9例(81.8%)、假腔内血栓形成5例(45.5%);(2)壁内血肿1例平扫表现为主动脉壁新月形增厚,密度增高,无内膜撕裂,增扫无强化,为新月形相对较低密度;(3)真性动脉瘤7例均显示动脉瘤大小、范围、腔内附壁血栓及钙化;(4)2例假性动脉瘤均显示动脉旁混杂密度肿块,增扫肿块不均匀强化,强化团与动脉有颈相连。所以16排螺旋CT轴位及3D重建图像,能全面显示主动脉病变的病理解剖改变,为临床治疗提供精细的影像学信息。
The purpose of this study was to describe the 16-slice detector spiral computer tomography (SCT) technique and imaging features of aortic aneurysms. We analyzed 21 patients documented aortic aneurysms, that underwent unenhanced and contrast-enhanced spiral CT with a 16-slice scanner (Sensation 16), and threedimensional reconstructions were performed for CT scan images. The results showed that: (1) Aortic dissection (11 cases), included the true and false lumen (11 cases, 100%), intimal flaps (11 cases, 100%), intimal tear (9 cases, 81. 8%) and thrombosed false lumen (5 cases, 45. 5%); (2) Intramural hematoma, unenhanced CT depicted crescent-shaped areas with high attenuation extending along the walls of the aorta, no definable intimal flap, while contrast-enhanced CT showed no enhancement of attenuation in the crescent-shaped areas; (3) True aortic aneurysms (7 cases), CT revealed the size, range, thrombosis and calcification of all aneurysms; (4) Pseudoaneurysms (2 cases), the enhanced part of the inhomogeneous masses beside the aorta connected with the aorta shown on contrast-enhanced CT. Therefore, 16-slice detector SCT axial and three-dimensional images can exactly reveal the pathological and anatomical features of aortic aneurysms, and provide detailed imaging information for clinical therapy.
出处
《生物医学工程学杂志》
EI
CAS
CSCD
北大核心
2007年第1期50-54,共5页
Journal of Biomedical Engineering