期刊文献+

生物医用钛合金TiN涂层微磨粒磨损及耐蚀性初步研究 被引量:3

An Elementary Study on Micro-scale Abrasive Wear and Corrosion Properties for TiN Coatings of Medical Titanium Alloys
下载PDF
导出
摘要 对生物医用Ti6Al4V合金表面TiN涂层机械力学性能进行了研究,在分析力学性能的基础上,考察了TiN涂层在蒸馏水和Hank’s模拟体液中的耐磨性,并在Hank’s模拟人体体液中研究了TiN涂层在静态环境中的腐蚀行为。结果表明:在Ti6Al4V合金表面沉积TiN涂层后,其耐磨性和耐蚀性大大提高,有利于改善钛合金在人体环境中的使用寿命。 Mechanical properties of TiN coatings on the surface of medical Ti6A14V alloys were researched. Wear prop erties of TiN coatings in distilled water and Hank' s solution were investigated. Corrosion behaviour of the coatings in Hank' s solution was studied. The results show that wear and corrosion resistance are greatly improved when TiN coatings are deposited on the surface of Ti6A14V alloys, the life of implanted titanium alloys in physical environment can be improved.
出处 《润滑与密封》 CAS CSCD 北大核心 2007年第2期63-65,共3页 Lubrication Engineering
基金 国家自然科学基金资助项目(50405005) 新世纪优秀人才支持计划资助项目(NCET-05-0777)
关键词 TI6A14V合金 FiN涂层 Hank’s溶液 微磨粒磨损 腐蚀 Ti6A14V alloys TiN coatings Hank' s solution micro-scale abrasive wear corrosion
  • 相关文献

参考文献8

二级参考文献38

  • 1汪大林,罗远伦,戴玮霞,彭玉田.精密铸钛技术在义齿类铸件上的应用[J].铸造,1997,46(4):32-35. 被引量:9
  • 2张立德牟季美.纳米材料和纳米结构[M].科学出版社,2001.260-267.
  • 3Hu J, Ameen M, Leusink G, et al. Thin Solid Films, 1997, 308-309: 589-593.
  • 4Dion I, Rouais F, L1 Trut, el al. Biomaterials, 1993, 14 (3): 169-176.
  • 5Raimondi M T, Pietrabissa R. Biomaterials, 2000, 21 (9): 907-913.
  • 6Huang Nan, Chen Yuan-ru, Cai Guang-jun, et al. Surf. & Coat. Technol., 1996, 99: 127-131.
  • 7Wakai F, Kodoma Y, Sakaguchi S, et al. MRS Conference Proc. of International Meeting on Advanced Materials, Pittsburgh, PA: Materials Research Society, 1989. 7.
  • 8Glaiter H. Progress in Mater. Sci., 1989, 33: 223.
  • 9Wakai F, Kato H. Adv. Ceramic Mater., 1988, 3 (1): 71-78.
  • 10Patsalas P, Charitidis C, Logothetidis S. Surf. & Coat. Technol., 2000, 125: 335-340.