计算输电线路绕击跳闸率的新模型 被引量:18

New Model for Calculating the Shielding Failure Trip-Out Rate of Transmission Line
下载PDF
导出
摘要 为了能够更精确地计算输电线路的绕击跳闸率,将电磁暂态程序EMTP与蒙特卡罗法相结合,提出了一种新的计算输电线路绕击跳闸率的模型.该模型既能充分计及影响输电线路绕击跳闸的各种随机因素,又具有电磁暂态程序对过电压计算准确的优点,从而提高了计算绕击跳闸率的准确性.仿真计算结果表明,利用该模型所得到的绕击跳闸率与实际值的相对误差在10%以内.因此,该模型较规程法能更好地反映输电线路绕击跳闸的实际情况. To evaluate the shielding failure trip-out rate of the transmission lines accurately, a new model combining electromagnetic transient program (EMTP) simulation with Monte Carlo method is presented, where all random factors are taken into account and the higher accuracy for electromagnetic transient analysis of EMTP is kept. The simulated result shows that the relative error between the calculated result and the on site value gets within 10% to describe the trip-out more actually.
出处 《西安交通大学学报》 EI CAS CSCD 北大核心 2007年第2期223-227,共5页 Journal of Xi'an Jiaotong University
关键词 绕击跳闸率 蒙特卡罗法 规程法 电磁暂态程序 shielding failure trip-out rate Monte Carlo method regular method electromagnetic transient program
  • 相关文献

参考文献8

  • 1钱冠军,王晓瑜,丁一正,刘兆林,包建强.500kV 线路直击雷典型事故调查研究[J].高电压技术,1997,23(2):72-74. 被引量:101
  • 2Eriksson A J.The incidence of lightning strikes to power line[J].IEEE Trans on Power Delivery,1987,2(3):871-886.
  • 3中华人民共和国电力工业部.DL/T 620-1997交流电气装置的过电压保护和绝缘配合[S].北京:中国电力出版社,1997.
  • 4Transmission and Distribution Committee of the IEEE Power Engineering Society.IEEE guide for improving the lightning performance of transmission lines[M].New York:The Institute of Electrical and Electronics Engineers Inc,1997.
  • 5张颖,高亚栋,杜斌,施围.输电线路防雷计算中的新杆塔模型[J].西安交通大学学报,2004,38(4):365-368. 被引量:82
  • 6Martinez J A,Castro-Aranda F.Lightning performance analysis of overhead transmission lines using the EMTP[J].IEEE Trans on Power Delivery,2005,20(3):2200-2210.
  • 7张志劲,司马文霞,蒋兴良,孙才新,舒立春.超/特高压输电线路雷电绕击防护性能研究[J].中国电机工程学报,2005,25(10):1-6. 被引量:183
  • 8Lightning and Insulator Subcommittee of the T&D Committee.Parameters of lightning strokes:a review[J].IEEE Trans on Power Delivery,2005,20(1):346-358.

二级参考文献20

  • 1王晓瑜.几种雷电屏蔽分析模型物理基础的研究[J].高电压技术,1994,20(1):12-16. 被引量:27
  • 2王晓瑜.雷电屏蔽性能的模拟试验和分析模型的研究[J].高电压技术,1994,20(2):48-54. 被引量:30
  • 3杨瑞棠.广州蓄能水电站500 kV变电站雷电入侵波的保护[A]..2000年电气学术交流会论文集[C].北京:中国水利水电出版社,2000..
  • 4雷电.Golde R H[M].北京:水利电力出版社,1983..
  • 5DL/T620/1997.交流电气装置的过电压保护和绝缘配合[S].[S].,..
  • 6Eriksson A J. An improved electrogeometric model for transmission line shielding analysis[ J ]. IEEE Trans. on Power Delivery, 1987,2(3) : 859 - 870.
  • 7Dellera L, Garbagnati E. Lightning stroke simulation by means of the leader progression model. Part Ⅰ : Description of the model and evaluation of exposure of free-standing structures[ J ]. IEEE Trans. on Power Delivery, 1990, 5(4) : 2009 - 2017.
  • 8Dellera L, Garbagnati E. Lightning stroke simulation by means of the leader progression model. Part Ⅱ : Exposure and shielding failure evaluation of overhead lines with assessment of application graphs[ J ]. IEEE Trans. on Power Delivery, 1990, 5(4) : 2023 - 2029.
  • 9Rizk F A M. A model for switching impulse leader inception and breakdown of long air gap[ J ]. IEEE Trans. on Power Delivery, 1989,4(1) : 596 - 603.
  • 10Eriksson A J. The incidence of lightning strikes to power line[ J ]. IEEE Tram.on Power Delivery, 1987, 2(3) : 871 - 886.