根据燃煤热电厂工艺设置的要求和所使用原料的性质,分析了燃煤热电厂的火灾危险性,用事故树方法分别对输煤皮带火灾、锅炉燃烧室爆燃、汽轮机油泄漏火灾、电缆火灾等4个生产单元的火灾危险性进行了定性分析和定量计算,并根据分析结果针对性地提出了防火措施。
In this paper fire hazards in coal power plant are analyzed, fault tree analysis method is applied to respectively conduct qualitative and quantitative calculations on belt fires, boiler explosion, gas leakage fires and cable fires and according to the analyzed results some fire prevention measures are put forward.
出处
《工业安全与环保》
2007年第2期54-57,共4页
Industrial Safety and Environmental Protection