期刊文献+

导航辅助下椎弓根螺钉置入的应用现状 被引量:1

下载PDF
导出
摘要 目的导航系统是一种新兴的科技,外科导航系统尤其是脊柱外科导航系统给骨科医生带来了前所未有的发展空间,使手术更加准确,更加容易。本文就导航系统发展历史,原理,及其在椎弓根螺钉置入方面的应用现状做一综述。
作者 李野 郭春杰
出处 《颈腰痛杂志》 2007年第1期49-51,共3页 The Journal of Cervicodynia and Lumbodynia
  • 相关文献

参考文献25

  • 1Kalfas IH,Kormos Dw,Murphy MA,et al.Application of frameless stereotaxy to pedicle screw fixation of the spine[J].J Neurosury,1995,20(4):497-500.
  • 2Villalobs H,Germano IM.clinical evaluation of multimodality in frameless stereotaxy[J].Comput Aided Surg 1999,4(1):45-49.
  • 3Murphy,et al.Application of screw fixation of the spine[J].J Neurosury,1995,83(4):641-647.
  • 4Foley KI,Smith MM.Image-guided spine Surgery[J].Neurosury Clin North Arm.1996,7(2):171-186.
  • 5Brodwater BK,Roberts.DW,Nakajima T,et al.extracranial application of the frameless stereotactic operating microscope:experience with lumbar spine[J].Neurosurg,1993,32(2):209-213.
  • 6Amiot Lp,labelle H,De Guige JA,et al.Computer-assisted pedicle screw fixation.A feasibility study[J].Spine,1995,20(10):1208-1212.
  • 7winkler D,Vitzthum HE,seifert V.spinal markers:a new method for increasing a new way in spinal Navigation[J].comput Aided sury,1999,4(2):101-104.
  • 8Hazan EJ.Computer -assisted orthopaedic Surgery:a new paradigm[J].Tech in orthop,2003,18(2):221-229.
  • 9Holly LT,Foley KT.Intrapoperative spinal navigation[J].Spine,2003,28(suppl,15):654-661.
  • 10Laine T,Lund T,Ylikoski M,et al.Accuracy of pedicle screw insertion with and without computer assistance:randomized controlled clinical study in 100 consecutive patients[J].Eurspine J,2000,9(3):235-240.

二级参考文献9

  • 1田伟.使用计算机导航技术辅助脊柱骨折和不稳定的固定手术[J].中华创伤骨科杂志,2004,6(11):1218-1219. 被引量:23
  • 2Winkler D,Vitzthum HE,Seifert V.Spinal markers:a new method for increasing accuracy in spinal navigation [J].Comput Aided Surg, 1999,4(2): 101-104.
  • 3Laine T, Lund T,Ylikosik M. Accuracy of pedicle screw insertion with and without computer assistance:a randomised controlled clinical study in 100 consecutive patients[J].Eur Spine J ,2000,9(3 ) :235-240.
  • 4Arand M,Hartwig E,Hehold D. Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws:a prospective clinical study [J].Unfallchirurg,2001,104 ( 11 ):1076-1081.
  • 5Laine T,Lund T,Ylikoski M,et al. Accuracy of pedicle screw insertion with and without computer assistance:a randomized controlled clinical study in 100 consecutive patients[J].Eur Spine J,2000,9(3) :235-240.
  • 6Kalfas IH,Kormos DW,Murphy MA,et al.Application of frameless stereotaxy to pedicle screw fixation of the spine [J].J Neurosurg, 1995,20 (4): 497-500.
  • 7Amoit LP, Labell H, DeGuise JA. Computer-assisted pedicle screw fixationa:a feasibility study[J].Spine, 1995,20(10): 1208-1212.
  • 8Ebmeier K,Giest K,Kalff R.Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine[J].Acta Neurochir,2003,85 (Suppl): 105-113.
  • 9Arand M,Kinzl L,Gbehard F.Sources of error and risks in CT based navigation[J].Orthopade,2002,31 (4) :378-384.

共引文献14

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部