采用清华大学研制的建筑能耗模拟软件DeST,应用正交模拟实验计算方法,针对办公写字楼建筑型式及空调系统,综合分析该类建筑最优节能设计方案及空调系统的年累计耗冷量、年平均COP、小时用燃气量、燃气的“一次能”消耗量、以及由于消耗大量的“一次能”而向都市大气环境排放的温室气体(CO2、SOx、NOx),以实现对该类建筑最佳节能设计型式、空调系统能量消耗和环境影响的综合分析与评价的目标。
Using QingHua University DeST software and the orthogonal experimental method, in connection with building types and central air conditioning systems of office and business buildings the optimum design scheme of energy saving for this kind of buildings and some parameters of the air conditioning systems, such as the year accumulated cooling quantity, the year average COP, the hour gas consumption, the consumption amount of "Primary Energy", and the discharge amount of some main "Green House Effect" gases(CO2, SOx, NOx ) to outdoor atmosphere, are analyzed synthetically. The results can realizes a goal of the best energy saving proposal, and the comprehensive evaluation of the air-conditioning syslems energy consumption and the effect of environment.
出处
《建筑科学》
北大核心
2007年第1期14-17,共4页
Building Science
基金
河北省教育厅科研项目(2002264)
关键词
DeST
正交模拟实验
空调系统
一次能耗
环境负荷
DeST
orthogonal experimental method
central air conditioning systems
consumption amount of "Primary Energy"
environment load