目的:对Sysmex XE-2100全自动血细胞分析仪检测有核红细胞的性能进行评估。方法:以XE-2100血细胞分析仪测定含有有核红细胞的标本观察其重复性,线性范围,携带污染率,结果的稳定性及与手工法的比较。结果:XE-2100血液分析仪测定有核红细胞的重复性好,有核红细胞在(0-33.1)×10^9/L范围内线性良好,在室温条件下有核红细胞数值在48h内变化差异无显著性,携带污染率较低,与显微镜计数结果之间有良好的相关性(r=0.967)。结论:XE-2100血液分析仪测定有核红细胞具有快速,客观,结果较准确,精密度高等特点,适合临床检测有核红细胞。
Objective: To evaluate the performance of sysmex XE- 2100 automatic blood cell cytoanaiyze on nucleatod red blood cell detection. Methods:To observe the reproducibility,linear range, carry over rate of XE -2100 automatic blood cell cytoanalyze on nucleated red blood cell detection, and compare with handmethods. Results:This method has a fine reproducibility, and a fine linear range (0 - 33. 1 × 10^9/L), under room temperature the results have no significance difference within 48 hours. Carry over rate was lower than hand method, and had good correlation with microscope counted number( r =0. 967 ). Conclusion:The methods of XE-2100 automatic blood cell cytoanalyze detection on nucleated red blood cell was quick, objective, accurate and high precision which is suitable for clinical detection on nucleated red blood cell .
出处
《中国卫生检验杂志》
CAS
2007年第1期106-107,共2页
Chinese Journal of Health Laboratory Technology
关键词
全自动血液分析仪
有核红细胞
Automatic blood cell cytoanalyze
Nucleated red blood cell