摘要
介绍了碱性处理技术改善发电机内冷水水质的基本原理以及该技术在吴泾第二发电有限责任公司2×600 MW机组上试验研究和成功应用的情况,提出了将氢型混床改为碱化混床运行时应考虑对系统改进和运行控制的若干建议。
The basic working principle of using alkalization treatment technology to improve the quality of the internal cooling water in generators is recommended, and application of the technology to 2 × 600 MW units of Shanghai Wu-jing No. 2 Power Generation Co. , Ltd. is illuminated. Suggestions on system updating and operation control when the H/OH mixed bed is changed into alkalization mixed bed are proposed.
出处
《华东电力》
北大核心
2007年第1期84-87,共4页
East China Electric Power
关键词
发电机
内冷水系统
碱性处理
generator
internal water cooling system
alkalization treatment