期刊文献+

适合电压跌落的DFIG与电网连接方式对比分析 被引量:2

Comparison and Analysis of DFIG Suit for Voltage Drop and Power Grids Connecting Methods
原文传递
导出
摘要 电网运行新规则要求风力发电机在电网电压跌落的情况下仍与电网相连接,这需要根据风力发电机同电网的具体连接情况,采取适当的保护措施,安装必要的设备来实现。例如:安装Crowbar低压旁路系统、采用带UPS逆变器的电路和带UPS逆变器的Crowbar电路等。这些保护措施各有其优缺点,在具体设计时,应根据实际情况合理选择。 The new regulations of power grid operation require that wind turbine-generator keep connected with the grids even in the situation of grid voltage drop. Based on the connection between wind turbines and grids, proper protective measures and necessary equipment, such as equipping with Crowbar low voltage bypass system, using circuits with UPS inverter, or using Crowbar circuit with UPS inverter, are needed. These protective measures have their own merits and disadvantages, thus, they have to be chosen carefully in the design process.
出处 《电力建设》 2007年第2期31-34,共4页 Electric Power Construction
关键词 变速恒频 双馈感应发电机 电压跌落 CROWBAR电路 variable-speed constant-frequency doubly fed induction generator (DFIG) voltage drop Crowbar circuit
  • 相关文献

参考文献9

  • 1Enslin, J.H.R., J. Knijp, C.P.J. Jansen, and P. Bauer, "Integrated ap preach to network stability and wind energy technology for on-shore and off-shore applications". Power Quality Proceedings, May 2003:185-192
  • 2Ledesma, P.;Usaola, J. "Doubly Fed Induction Generator Model for Transient Stability Analysis". IEEE Tran. on Energy Conversion,2005,20(2) : 388-397
  • 3Bing Xie, Fox, B.; Flynn, D. "Study of fault fide-through for DFIG based wind turbines". IEEETran.on Electric Utility Deregulation,2004,1:411-416
  • 4Magueed, F.A.; Sannino, A.; Svensson, J. "Transient performance of voltage source converter under unbalanced voltage dips ".PESC04,2004,Vol.2 : 1163-1168
  • 5Sun, T., Chen, Z. " Blaabjerg, F. Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault". PESC 04.,2004,Vol.3 : 20-25
  • 6J.Niiranen. "Voltage ride through of a doubly-fed generator equipped with an active Crowbar". EPE-PEMC,2004,Riga, Latvia.
  • 7J.Niiranen. "simulation of doubly fed induction generator wind turbine with an active Crowbar". European power electronic-PEMC 2004,(EPE-PEMC),11th international European power ELEctronic and motion control,September 2004,Riga Latvi
  • 8Wang, S., Ding, Y. Stability Analysis of Field Oriented Doubly-Fed Induction Machine Drive Based on Computer Simulation. Electric Machines and Power Systems, 1993: 11-24
  • 9C. Abbey, G. Joos. "Effect of Low Voltage Ride Through (LVRT) Characteristic on Voltage Stability".

同被引文献13

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史