摘要
着重阐明了闸孔相对开度e/H及相对作用水头H/H_p对流量系数μ_0的影响.并通过具体数据说明在堰型、闸门型式、位置及平板闸门切口方向一定的情况下,闸门相对开度e/H及相对作用水头H/H_p均为流量系数μ_0的主要影响因素.同时用最小二乘法得出流量系数μ_0与闸孔相对开度e/H的关系式呈双曲线型,而不是直线方程.
This article explains that the discharge coefficient for steady free out flow under a highdam spillway gate is mainly influenced by relative gate opening and relative head On thebasis of experimental study a relationship between discharge coefficient po and relative gateopening H developed. The discharge coefficient formula obtained is not a rectilinear equationbut a hyperbolic one.
出处
《武汉水利电力大学学报》
EI
CSCD
1996年第6期16-20,共5页
Engineering Journal of Wuhan University
关键词
流量系数
闸孔出流
相对开度
相对水头
discharge coefficient
outflow
gate opening
relative head