摘要
介绍一种新型水电站综合优化多变量自校正调节器,它可使频率调节和负荷优化分配同时实现.在每一次调节完毕后,频率和功率均达到最优,在调节过程中负荷分配始终遵循优化分配原则,从而缩短了调节时间。
An optimal multi objective self tuning regulator for hydropower station is developed by using adaptive control theory in this paper.The frequency regulation and load distribution are both considered as the cost function,the frequency can be combined with loadwto control the system.By this regulator,the optimal dynamic feature of the frequency and load distribution among the turbine generators can be obtained by the end of every regulation process,so the time is reduced and the dynamic feature of frequency is improved.
出处
《水电能源科学》
北大核心
1996年第4期264-270,共7页
Water Resources and Power
关键词
频率调节
负荷最优分配
自校正调节器
水电站
frequency regulation,optimal load distribution,self tuning regulator