目的建立儿童咳液的质量控制方法。方法采用Alltech C18柱(250mm×4.6mm,5μm),乙腈-0.1%磷酸溶液(5:95)为流动相,检测波长为207nm。结果盐酸麻黄碱在1.55—24.86μg·mL。。间有良好的线性关系(r=0.9997),加样平均回收率为99.15%,RSD为0.82%(n=6)。结论本法简便、快速、重复性好,可作为产品的定量分析方法。
OBJECTIVE To establish a HPLC method for controlling the quality of Ertongke Liquid. METHODS In this method Alhech C18 colunm(250mm × 4.6mm,5μm) was used, and acetonitfile-0.3% phosphoric acid(5: 95) as mobile phase, the detection wavelength was at 207nm. RESULTS Ephedrine hydrochloride had a good linear relationship at the range of 1.55μg· mL^-1 - 24.86μg ·mL^-1(r =0.9997) ;The average recovery of ephedrine hydroehloride was 99.15% and RSD was 0.82% (n =6). CONCLUSION This method is simple with good reproducibility and can be used for the qualitative analysis.
出处
《中国现代应用药学》
CAS
CSCD
北大核心
2007年第1期64-66,共3页
Chinese Journal of Modern Applied Pharmacy