期刊文献+

基于Agilent86100取样示波器的时域网络分析系统(英文) 被引量:2

Time-domain network analytic system based on Agilent 86100 sampling oscilloscope
下载PDF
导出
摘要 本文根据Nose-to-Nose校准技术的基本原理,提出了利用NTN技术和Agilent86100取样示波器,构建时域网络分析系统的新方法。该方法成功地实现了对标称带宽50GHz的同轴适配器、同轴电缆等器件的测量。通过数字信号处理不仅可以得到这些器件的全部时域特性(冲激响应、阶跃响应、上升时间和过冲等),而且还能得到其全部频域特性(幅频特性、相频特性和带宽等)。扫频源比对实验证明该方法是有效的。 A new method which constructs time-domain network analytic system by using of Nose-to-Nose technology and Agilent 86100 broadband sampling oscilloscope is put forward in this paper based on the basic theory of Nose-to- Nose calibration technology. Coaxial adapter and cable whose nominal bandwidth is 50 GHz have been measured by this system. Then, time-domain characteristics (e. g. impulse response, step response, rise time and overshoot) and frequency-domain characteristics (amplitude response, phase response and bandwidth) could be obtained by digital signal processing. Swept-sine method comparison experiments verified that the method is effectual.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2007年第2期241-245,共5页 Chinese Journal of Scientific Instrument
关键词 Nose-to—Nose 时域网络分析系统 宽带取样示波器 Nose-to-Nose (NTN) time-domain network analytic system broadband sampling oscilloscope
  • 相关文献

参考文献11

  • 1吴迪,刘明亮,朱江淼.基于平衡取样电路的高速脉冲发生器[J].电子测量技术,2006,29(2):7-10. 被引量:6
  • 2朱江淼 刘明亮 李洋.基于Agilent86100取样示波器的高速脉冲源[J].电子测量与仪器学报,2006,:362-365.
  • 3LIU M L,WANG Y T, YU Y, et al. Extended "Nose-to-Nose" calibration procedure [ C ]. ICEMI 2005,2005,2 :641-645.
  • 4VERSPECHT J, RUSH K. Individual characterization of broadband sampling oscilloscopes with a "Nose-to-Nose" calibration procedure [ J ]. IEEE Transaction on Instrumentation and Measurement, 1994, IM_43 (2) : 347-354.
  • 5VERSPECHT J. Broadband sampling oscilloscopes characterization with the " Nose-to-Nose" calibration procedure: a theoretical analysis [J]. IEEE Transaction on Instrumentation and Measurement, 1995,44 ( 6 ) : 991-997.
  • 6ZHU J M, LIU M L, LU F. A novel research of nose-to-nose calibration foundation [ C ]. 6th International Symposium on Test and Measurement, Dalian, China, 2005,9 :8183-8187.
  • 7卢峰,刘明亮,郁月华.带有连接电缆的“NTN”校准技术[J].计量学报,2005,26(1):66-69. 被引量:3
  • 8RUSH K, DRAVING S,KERELY J. Characterizing high-speed oscilloscopes [ J ]. IEEE Spectrum, September 1990: 38-39.
  • 9朱江淼,刘明亮,卢峰.Nose-to-nose校准技术的理论分析[J].电子学报,2005,33(3):480-483. 被引量:10
  • 10赵科佳,刘明亮,郁月华,缪京元.宽带取样示波器上升时间与带宽的转换系数的研究[J].计量学报,2006,27(2):160-163. 被引量:11

二级参考文献29

  • 1朱江淼,刘明亮,卢峰.Nose-to-nose校准技术的理论分析[J].电子学报,2005,33(3):480-483. 被引量:10
  • 2Verspecht J, Rush K. Individual characterization of broadband sampling oscilloscopes with a nose-to-nose calibration procedure[J]. IEEE Trans on IM, 1994, 43(2) :347 ~ 354.
  • 3Hale P D, et al. Estimating the magnitude and phase response of a 50 GHz sampling oscilloscope using the "nose-tonose" method[ A ]. Proc 55th ARFTG Conference Digest [ C ].Boston, MA :2000,35 ~ 42.
  • 4Gans W L. The measurement and deconvolution of time jitter in equivalent-time waveform samplers [ J]. IEEE Trans on IM, 1983, 32(3) :126 ~ 133.
  • 5Rush K, et al. Characterizing high-speed oscilloscopes[J].IEEE Spectrum, 1990,27(9) :38 ~ 39.
  • 6Ken Rush,Steve Draving,John Kerely.Characterizing high-speed oscilloscopes[J].IEEE Spectrum September 1990.38-39.
  • 7Jan Verspecht.Broadband sampling oscilloscopes characterization with the nose-to-nose calibration procedure:A theoretical analysis[J].IEEE Transaction on Instrumentation and Measurement,1995,44(6):991-997.
  • 8Dylan F Williams,Kate A Remley.Analytic sampling-circuit model[J].IEEE transactions on microwave theory and techniques,2001,49(6):1013-1019.
  • 9Donald C DeGroot,Paul D Hale.Analysis of Interconnection Networks and Mismatch in the Nose-to-Nose Calibration[C].55th ARFTG Conference Digest.2000.116-121.
  • 10SEDKI M RIAD.Modeling of the HP-1430A feed-through wide-band (28-ps) sampling head[J].IEEE Transactions on Instrumentation and Measurement,1982,31(2):110-115.

共引文献24

同被引文献7

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部