摘要
结合工程案例,从基层结构、保温砂浆材料、其他因素三方面分析了外墙内保温材料石膏珍珠岩类保温砂浆使用过程中的开裂原因,并介绍了相应的预防措施,通过工程实践,总结了保温砂浆的施工注意事项。
Combined with practical engineering, this paper analyzes the causes of cracks in the utilization process of external wall internal heatinsulation material, plaster-perlite thermal insulation mortar, from the structure of base course, thermal insulation mortar and other factors, introduces relevant preventive measures for them, and summarizes engineering attentions of heat-insulation mortar by practical project.
出处
《山西建筑》
2007年第1期132-133,共2页
Shanxi Architecture
关键词
保温砂浆
基层结构
石膏
加气混凝土
heat-insulation mortar, structure of base cottrse, plaster, aerated concrete